1-6. Matching Connectors and Cables

Use the following connectors, cables or equivalents when connecting cables to the unit.
Model name Panel indication
MVS-6520
OUT 1-16 (MVS-6520/3000)
/6530
OUT 1-16, 17-32 (MVS-6530)
/3000
IN 1-16, 17-32 (MVS-6520/3000)
IN 1-16, 17-32, 33-48 (MVS-6530)
S-BUS
REF IN
REMOTE 1-4
REMOTE S1, S2
SERIAL TALLY
TARRY/GPI IN 13-18 OUT 33-48
TARRY/GPI IN 7-12 OUT 17-32
TARRY/GPI IN 1-8 OUT 1-16
MVS
*3
UTIL (SW)
*3
UTIL (SCU)
*3
UTIL (FM)
FM DEVICE
*1: The following crimp contact is required for the plug.
AWG#18 to #22: 1-566-493-21
AWG#22 to #24: 1-564-774-11
AWG#24 to #30: 1-564-775-11
*2: Conforms to the IEEE 802.3 Ethernet 100BASE-TX standards.
*3: n
UTIL (SW), UTIL (SCU) and UTIL (FM) are currently not supported.
Fix the BNC cable connected to the BNC connector on the rear panel to the rack and the like in order to avoid placing a load on the
BNC connector. If the BNC connector is continuously used with a load placed, the BNC connector and BNC cable may be damaged.
MVS-6520
Connector name
Matching connector and cable
Name
BNC, 75 Z
Belden 1694 coaxial
cable
D-sub 9-pin,
D-sub 9-pin, male
Female
Connector 9-pin, male
Junction shell 9-pin
D-sub 25-pin,
D-sub 25-pin, male
Female
Connector 25-pin, male
Junction shell 25-pin
_
RJ-45 modular
*2
jack
_
USB 2.0 Type A
receptacle 4-pin
Sony parts No.
_
*1
1-560-651-00
1-561-749-00
*1
1-560-904-11
1-563-377-11
_
_
1-9 (E)