FAULT CODES

Error Codes may appear and these are:
Remote
Power
LCD
(Red LED)
Err
__ __ __
(Slow Flash)
F01
– – – – – –
(Fast Flash)
F02
– – – – – –
(Fast Flash)
F03
– – – – – –
(Fast Flash)
CLd
HtC
OTP
OCP
Charging
Full
(Blue LED)
(Green LED)
OFF
OFF
OFF
ON
– – – – – –
OFF
(Fast Flash)
ON
– – – – – –
(Fast Flash)
Fault
Short circuit or
reverse connection
of the clips.
Bulk charging has
timed out and stopped
after 10 hours.
Soft Start has timed
out as the battery has
not reached 10.0V
after 2 hours.
Absorption has been
charging for more
than 20 hours and is
now in float mode.
Battery Temp is less
then 0°C. Charging at
reduced current.
To protect the battery.
Battery Temp is greater
than 45°C the charger
voltage is reducing, to
protect the battery.
The charger has
overheated (>70°C)
and has switched off.
The charger has
encountered an error.
Remedy
Check clips are not
touching each other
OR
Check the clips are
correctly connected
to the battery.
Battery may be faulty.
Battery may be faulty,
check the battery or try
and charge again.
Battery may be faulty or
there could be a load on
the battery.
Warm the battery up.
Cool the battery down.
Ensure adequate
ventilation around the
charger.
Contact Brown & Watson
International.