DESCRIZIONE DEI COMPONENTI
PANNELLO CONTROLLO
Heater
The heater switches on automatically when the spa water temperature is one degree Centigrade lower
than the value set on the control panel.
If not already in operation, the recirculation pump is activated automatically.
Ozonizer
The ozonizer is activated by the recirculation pump and is disabled automatically when the SPA
function is on.
When the ozonizer is in operation, the related LED is on.
Warnings
Temperature warning - If the water temperature in the spa exceeds 42° C all functions are disabled
and the message "HI" and the temperature are displayed alternately.
The warning and the system reset automatically when the temperature falls to below 40° C.
Temperature sensor warning - The sensor measures the water temperature in the spa and ensures it
is maintained.
The temperature ranges from 5° C to 45° C. Outside this range the system is blocked and the message
"ER" is displayed.
In this case the tub will have to be shut down, then started up again after waiting 30 seconds, using the
product's main switch.
The message "ER can also indicate a fault in the temperature sensor.
No flow warning - The flow alarm serves to protect the heater and the recirculation pump.
There are two warning types: no flow and flow sensor fault.
If there is no water flow the heater is disabled, the recirculation pump remains active and the message
"FL" and the temperature are displayed alternately.
The warning and the system reset automatically when normal working conditions are restored.
The message "FL" can also indicate a fault in the temperature sensor.
Pg. 16
treesse
Automatic cleaning - Begins automatically after every 350 hours of
recirculation pump operations.
If the filter is blocked a cleaning cycle is triggered automatically.
If the problem persists, the system blocks all functions and the
message "FL" is displayed.
In this case the tub will have to be shut down, then started up again
after waiting 30 seconds, using the product's main switch.
The cleaning cycle can only be stopped by turning off the product at
the mains.
Manual cleaning - The function is activated manually by pressing the
SPA button for 10 seconds.
There is no limit to the number of cycles activated.
treesse
Need help?
Do you have a question about the FUSION SPA and is the answer not in the manual?