COMPONENTS DESCRIPTION
CONTROL PANEL
ON mode
In ON mode the spa is kept ready for use by the user.
If there is not water level warning, the recirculation pump remains on to filter the water.
On start-up, the control panel goes to the same status as before the last shutdown.
The change to ON from STANDBY mode is made by pressing the scroll DOWN and UP buttons
together.
STANDBY mode
STANDBY mode is used when the spa is not expected to be used for some time, and maintains a
temperature (chosen by the user) lower than the product's normal usage temperature.
The default value is 25° C.
In this mode the functions are disabled and the recirculation pump becomes active, provided there are
no water level warnings, to maintain the temperature or filter the water.
To enter and exit STANDBY mode, the scroll UP and DOWN buttons have to be pressed together.
STANDBY mode is also maintained in the event of blackouts or power surges.
When the spa is in STANDBY mode the "SBY" message is displayed.
If the heater is in operation, the related LED is on.
To change the temperature in STANDBY mode press the scroll UP and DOWN buttons.
The minimum temperature that can be set is 13° C.
For filtering with disinfection while in STANDBY mode, the pump and the ozonizer are activated twice a
day (every 12 hours).
During filtering the related LED is on.
Pg. 14
treesse
Spa
The spa function is activated by pressing the SPA button.
The function is confirmed when the SPA LED is on.
This function can be activated only when the water has reached the
required level.
The spa function is disabled when DRAINING is on.
If not stopped via the control panel, the function switches off
automatically after 20 minutes.