Operation
Flush the Gun
To reduce the risk of serious injury, including splashing
fluid in the eyes or on the skin, or static electric dis-
charge when flushing:
• Be sure the entire system, including flushing pails,
is properly grounded.
• Remove the tip guard and spray tip.
• Maintain metal to metal contact between the gun
and the flushing pail.
• Use the lowest possible pressure.
NOTICE
Always flush the pump and gun before the sprayed
fluid cures.
NOTE: This procedure requires a grounded pail of com-
patible flushing fluid.
1. Relieve pressure.
2. Remove the tip guard and spray tip. Soak and clean
the parts.
3. Single component systems only: Remove the pump
intake from the original pail. Put the pump intake in
a grounded pail of compatible solvent.
4. Start the pump at its lowest pressure.
5. Single component systems only: Trigger the gun
into the original pail. When flushing fluid appears,
release the trigger.
6. Two-component systems only: Trigger the gun into
a waste container. When flushing fluid appears
release the trigger.
8
ti19269a
7. Now trigger the gun into the flushing fluid supply
pail. Circulate the fluid until the system is thoroughly
flushed.
8. After gun is thoroughly flushed, relieve pressure.
3A2799C