Group and floor names
- Group name: Displays the group name. (Group object only)
- Floor name: Displays the name of the floor on which the group is distributed.
(For whole building, Whole building is displayed.)
Remote control operation prohibit setting: Displays the operation prohibit setting state of the local remote controller.
ON/OFF: Displays the current operation status by color. (Green: On, Red: Off)
Operation mode: Displays the current operation mode.
Temperature display
- Target set temperature: Displays the target set temperature.
- Indoor temperature: Displays the current indoor temperature.
Fan speed/vane/ventilation equipment display
- Fan speed:
- Vane:
- Louver:
- Ventilation equipment: Displays the interlocked ventilation unit status.
Operation section: Performs operation mode, target temperature, and wind setting and other operations.
Note:
- The newest information is displayed on the remote control screen only when this remote control screen was displayed.
(3) Remote control screen operation
ON/OFF
Perform ON/OFF switching by clicking the ON/OFF button.
ON (green)/OFF (red) are alternately switched each time the button is clicked.
Operation mode change
Switch the operation mode by clicking the Mode Set button at the operation section.
The operation mode is switched in Fan → Cool → Heat → Dry → Auto → Fan · · · order each time the button is clicked.
For ventilation group, the operation mode is switched in Auto → Heat ex. → By-Pass → Auto · · · order.
(The operation modes that can be changed depends on the setting.)
Set temperature change
Change the set temperature by clicking set temp. adjustment
(The range of temperatures that can be changed depends on the operation mode.)
Note:
- When the setting is different for each group, the following is displayed by operation from floor batch, whole building
batch, and block:
On/Off:
Operation mode: – –
Set temperature: – –
Fan Speed change
Change the wind velocity by clicking the Fan Speed button.
Fan Speed is switched in Lo → Mid 1 → Mid 2 → Hi → Lo · · · order.
For ventilation group, Fan Speed is switched in Lo → Hi → Stop → Lo · · · order.
(The changeable Fan Speed depends on the function setting.)
Vane change
Change the vane by clicking the Vane button.
The vane is switched in Horizontal → Down 60% → Down 80% → Down 100% → Swing → Horizontal · · · order.
(Whether or not there is a Swing and screen direction switching function depends on the function setting.)
*Ventilation group does not have this function.
Louver change
Change the louver by clicking the Louver button.
Louver is switched in On → Off → On · · · order.
(Whether or not there is a Louver switching function depends on the function setting.)
*Ventilation group does not have this function.
Displays the current fan speed.
Displays the current wind direction.
Displays the current louver status.