Placing on a surface
If you install the supplied tripod on the base of the fixture, you can stand the impression
S350 upright on a flat, stable, horizontal surface in any location where the fixture is not
accessible to the public and will not present any safety risks.
If necessary to prevent the fixture from moving or
falling, pass a ratchet strap, webbing or other suitable
bracing strap through the safety cable attachment
points in the base (see Figure 10) or the strap
attachment points in the tripod stand (see Figure 11)
and fasten it to secure anchoring points. Make sure
that the strap is tight enough to hold the fixture, but do
not distort attachment points by overtightening the
strap.
If the fixture may cause injury or damage if it falls,
secure it with a safety cable as described in 'Safety
attachment' on page 20.
Make sure that the head will not collide with anything
when it tilts and rotates.
Connecting to power
The AC mains power supply must include a connection to ground / protective earth. It
must be protected against ground / earth leakage and overload. The auto-sensing
power supply accepts AC power at 100-240 V, 50/60 Hz. Do not connect the fixture to
power at any other voltage or to an external dimmer.
The impression S350 has a 3-conductor Neutrik powerCON TRUE1 socket that accepts
AC power from a Neutrik powerCON TRUE1 female cable connector.
Although powerCON TRUE1 connectors support hot-plugging, it is still good practice to
shut down power to power cables or move Power ON/OFF switches to OFF before
connecting power cables to fixtures.
To connect the fixture to power:
Check that power to the power input cable is shut down or that the fixture's power
switch is set to OFF.
See Q in Figure 2 on page 11. Note the position of the keys and keyways on the
power cable connector and Mains In socket and align them with each other. Insert
the cable connector into the socket and twist clockwise to lock.
Before applying power by energizing the power cable and/or switching on the
power switch, check that the head is unlocked and can move freely and check
that nobody is looking directly into the front of the fixture.
Installing power connectors
It is possible to install a cord cap / mains power plug that is suitable for your local
convenience receptacles / power sockets on the supplied power input cable. If you
do this, check that the cord cap / plug is rated minimum 250 V, 16 A, that it has a
connection to ground / earth and that it has an integral cable grip. Follow the cord
cap / plug manufacturer's assembly instructions.