ABB 266CRH Instructions Manual page 73

Multivariable pressure transmitter with modbus communication
Hide thumbs Also See for 266CRH:
Table of Contents

Advertisement

266CRH / 266CRT, 266CSH / 266CST MULTIVARIABLE PRESSURE TRANSMITTER | OI/266CXX/MODBUS-EN REV. A
Optional text on display
An optional text will be shown automatically on the display with sending data to the registers 1001 to 1008. It allows displaying
strings in two lines written via MODBUS. The first text line is filed from register 1001 to 1004, the second text line is filed from
register 1005 to 1008.
It is possible to write all 8 registers in an access with the function WriteMultipleRegister (16).
The optional text lines can be disabled with the display menu an option 'USER TEXT'.
Address
Parameter
32 bit
16 bit
1001
User Text Line 1 Sign 1 & 2
1002
User Text Line 1 Sign 3 & 4
1003
User Text Line 1 Sign 5 & 6
1004
User Text Line 1 Sign 7
1005
User Text Line 2 Sign 1 & 2
1006
User Text Line 2 Sign 3 & 4
1007
User Text Line 2 Sign 5 & 6
1008
User Text Line 2 Sign 7
Data type
Read
Write (32 bit)
Usign16
03
Usign16
03
Usign16
03
Usign16
03
Usign16
03
Usign16
03
Usign16
03
Usign16
03
73
Function code
Write (16 bit)
06, 16
06, 16
06, 16
06, 16
06, 16
06, 16
06, 16
06, 16

Advertisement

Table of Contents
loading

This manual is also suitable for:

266csh266crt266cst

Table of Contents