Download Print this page

Kirby Morgan KM 97 Installation Instructions Manual page 4

Water shroud kit

Advertisement

Kirby Morgan Dive Systems, Inc.
1430 Jason Way Santa Maria, California 93455
Phone: 805/928-7772
www.KirbyMorgan.com email: kmdsi@KirbyMorgan.com
Bent Tube
11) Insert bent tube assembly into regulator inlet side and line up the bent tube mount nut to the side block.
The adapter sleeves have to be inserted onto the bent tube assembly and remain loose while the bent tube
is being installed. The channeled ends of the sleeves will be facing each other while installing the bent tube
assembly.
14) Complete installation of bent tube assembly. Refer to "1.1.4 Reinstallation of the Bent Tube Assembly"
on page BNT-2 from the KMDSI modular manual.
Fax: 805/928-0342
12) Swing the bent tube away from the side block and put the
adapter sleeve (short), P/N 550-572, onto the bent tube assem-
bly first, channeled end facing away from regulator inlet.
13) Fit the adapter sleeve, long, P/N 550-580, over the bent tube
assembly, channeled end facing away from the side block.
© ⅯⅯⅩⅧ Kirby Morgan Dive Systems, Inc. All Rights Reserved
®
Page 4 of 8
Document # 180117001

Advertisement

loading