Installation - Electrical Connection Oven - PizzaMaster PM 721 Owner's Manual

700 series, 800 series, 900 series, electric modular ovens
Table of Contents

Advertisement

Installation – Electrical connection oven
Electrical connection
For connection and correct fuse rating, see the
oven rating plate, the table for fuse protection
need and the attached electrical diagram.
After reading all above information, follow instruc-
tions below for correct electrical connection.
The earth potential equalizer screw has to be in-
stalled. The earth potential equalizer screw is located
on the backside next to the connecting cable.
1. Make sure electrical supply cor-
responds with that specified on
the oven rating plate
Remove the screws (6 pcs) that
secures the right-hand side panel,
and take off the panel.
14
Electrical Connection
2. Take the power supply cable
(depending on voltage the oven can
be connected with 1 power sup-
ply per deck or 1 power supply per
oven, power supply cable(s) is not
included) through the hole(s) on
the backsides right-hand side of the
oven and further to the connecting
terminal. An adequate restraining
must be used for each power supply
cable.
PizzaMaster®
Important!
For reasons of safety and the validity of the war-
ranty, all electrical work must be carried out by a
qualified electrician.
The oven must be connected via an external
main swich with min. 3 mm gap.
3. Following the appropriate electri-
cal wiring diagram confirming to
the oven rating plate, connect the
power supply leads to the field
terminal block.
Make sure all connections are
tight, then place back the right-
hand side panel.

Advertisement