Electrical Connection - PizzaMaster PM 351ED Instructions For Installation, Operation And Maintenance

Counter top oven
Table of Contents

Advertisement

Electrical connection

Important!
For reasons of safety and the validity of the war-
ranty, all electrical work must be carried out by a
qualified electrician.
The oven must be connected via an external main
switch with min. 3 mm gape of at least 3 mm for
each power supply cable.
Electrical connection - Standard width
Power and fuse ratings per oven
Model
400V 3N
PM 351ED
3/5A
PM 351ED-1
3/5A
PM 352ED
3/10A
PM 352ED-1
3/10A
PM 352ED-2
3/10A
PM 401ED
3/7A
PM 401ED-1
3/7A
PM 402ED
3/14A
PM 402ED-1
3/14A
PM 402ED-2
3/14A
PM 451ED
3/8A
PM 451ED-1
3/8A
PM 452ED
3/16A
PM 452ED-1
3/16A
PM 452ED-2
3/16A
PM 551ED
3/10A
PM 551ED-1
3/10A
PM 552ED
3/20A
PM 552ED-1
3/20A
PM 552ED-2
3/20A
Electrical connection - Double width
Power and fuse ratings per oven
Model
400V 3N
PM 351ED-DW
3/10A
PM 351ED-1DW
3/10A
PM 352ED-DW
3/15A*
PM 352ED-1DW
3/20A*
PM 352ED-2DW
3/20A*
PM 401ED-DW
3/14A
PM 401ED-1DW
3/14A
PM 402ED-DW
3/20A*
PM 402ED-1DW
3/27A*
PM 402ED-2DW
3/27A*
PM 451ED-DW
3/16A
PM 451ED-1DW
3/16A
PM 452ED-DW
3/24A*
PM 452ED-1DW
3/32A*
PM 452ED-2DW
3/32A*
*
Model not provided with a power supply cable.
** This model requires 2 separately electrical
connections each protected with indicated fuse.
Model not provided with a power supply cable.
On request ovens can be delivered with different Voltage than above.
6
230V 1N
230V 3AC
208V 1AC
10A
3/9A*
15A
3/9A*
20A*
3/14A*
25A*
3/17A*
30A*
3/17A*
14A
3/12A*
20A*
3/12A*
27A*
3/17A*
33A*
3/23A*
40A*
3/23A*
16A
3/14A*
24A*
3/14A*
32A*
3/21A*
40A*
3/28A*
-
3/28A*
20A*
3/17A*
29A*
3/17A*
39A*
3/26A*
-
3/34A*
-
3/34A*
230V 1N
230V 3AC
20A*
3/13A*
29A*
3/17A*
20A**
3/13A**
29A**
3/17A**
29A**
3/17A**
27A*
3/18A*
40A*
3/23A*
27A**
3/18A**
40A**
3/23A**
40A**
3/23A**
32A*
3/21A*
-
3/27A*
32A**
3/21A**
-
3/27A**
-
3/27A**
PizzaMaster®
• Before connecting the oven see the ovens rating plate
and attached electrical diagram
• The oven has to be connected with the attached
power supply cable (1.5 m)
• The earth potential equalizer screw has to be
installed. The earth potential screw is located on
the backside next to the connecting cable.
208V 3AC
240V 1AC
11A*
3/10A*
10A*
17A*
3/10A*
14A*
22A*
3/15A*
19A*
27A*
3/19A*
24A*
33A*
3/19A*
28A*
15A*
3/13A*
13A*
22A*
3/13A*
19A*
30A*
3/20A*
26A*
37A*
3/25A*
32A*
44A*
3/26A*
38A*
18A*
3/15A*
16A*
27A*
3/16A*
23A*
35A*
3/24A*
31A*
44A**
3/30A*
38A*
53A**
3/31A*
46A*
22A*
3/19A*
19A*
32A*
3/19A*
28A*
43A**
3/29A*
37A*
53A**
3/37A*
46A*
64A**
3/37A*
55A*
208V 1AC
208V 3AC
240V 1N
22A*
3/15A*
32A*
3/19A*
43A*
3/29A**
54A*
3/37A**
64A*
3/37A**
29A*
3/20A*
44A*
3/26A*
59A*
3/39A**
73A*
3/50A**
87A*
3/51A**
35A*
3/23A*
52A*
3/30A*
70A*
3/46A**
87A*
3/60A**
104A*
3/60A**
*** Models possible to connect both to 230V 3~ and
400V 3N is not provided with a power supply cable.
240V 3AC
480V 3N
3/8A*
3/5A
3/9A*
3/5A
3/13A*
3/9A
3/16A*
3/9A
3/17A*
3/9A
3/11A*
3/6A
3/11A*
3/6A
3/17A*
3/12A
3/22A*
3/12A
3/22A*
3/12A
3/13A*
3/7A
3/14A*
3/7A
3/20A*
3/14A
3/26A*
3/14A
3/27A*
3/14A
3/16A*
3/9A
3/16A*
3/9A
3/25A*
3/17A
3/32A*
3/17A
3/32A*
3/17A
240V 3AC
480V 3N
19A*
3/13A*
3/8A
28A*
3/17A*
3/9A
38A*
3/25A*
3/16A*
47A*
3/32A*
3/16A*
56A*
3/32A*
3/16A*
26A*
3/17A*
3/11A
38A*
3/22A*
3/11A
51A*
3/34A*
3/22A*
63A*
3/44A*
3/22A*
76A*
3/44A*
3/22A*
31A*
3/20A*
3/13A
45A*
3/26A*
3/14A
61A*
3/40A*
3/26A*
75A*
3/52A*
3/27A*
90A*
3/52A*
3/27A*