Automatic door opener
All oven doors in the PizzaMaster 700, 800 and 900
series can be equipped with an automatic door opener
as an optional extra.
Each automatic door opener has a powerful 3-phase
motor that open or close the oven door alternately by
each press on the foot pedal.
This enables the baker to have both hands free when
loading or un-loading the oven. It also relieves the arms
and shoulders from the stress of opening the oven door
manually many many times during a working day.
The door opener has a mechanical safety clutch that
enables the oven door to be opened manually at all
times.
1. Connect the foot pedals air
hose at the front of the door
opener, secure the hose with the
provided cable tie (do not tighten
too hard, air must flow through
the hose to the air-switch inside
the box).
Electrical installation
The door opener requires a separate 3-phase 10A
electrical connection. Only one electrical connection is
necessary for up to 5 oven doors.
1. Make sure electrical supply corresponds with that
specified on the oven rating plate (separate rating
plate located on backside of the lowest door opener
box)
2. Remove the screws (10 pcs) that secures the lowest
door openers side panel, and take off the panel.
3. Feed the power supply cable(s) (provided by
customer) through the access holes on the right-
hand back of the door opener box and pull the cable
to the field terminal block.
4. Following the appropriate electrical wiring diagram
confirming to the oven rating plate, connect the
power supply leads to the field terminal block.
5. Make sure all connections are tight, then replace
the right-hand side panel.
The earth potential equalizer screw has to be installed.
The earth potential screw is located on the backside
next to the connecting cable.
Installation – Automatic door opener
For reasons of safety and the validity of the war-
ranty, all electrical work must be carried out by a
qualified electrician.
The automatic door opener must be connected via
an external main swich with min. 3 mm gap.