Specifications
Dimensions
Width
Depth
Height
Unit Shipping Weight
Ambient Information
CAUTION!
The 7UC100A and 7UD100A are for indoor use only.
Air Temperature
†
Water Temperature
Water Pressure
Relative Humidity
* Use outside of these limitations is misuse and will void warranty.
† Best performance is achieved between 80 F (27 C) and 50 F (10 C).
Plumbing
§ Water Inlet: 1/4" MPT
§ Optional Drain Accessory Kit (item# 00956375 or 00981977): 1/2" ID tubing
§ Water shut-off recommended within 5 ft (1.5 m) of dispenser
Water
WARNING!
Connect to potable water supply only.
§ Water Mineral Content:
– TDS: greater than 5 ppm (mg/l) but less than 400 ppm (mg/l)
– Hardness: Less than 200 mg/l (12 gpg)
§ Not recommended for use with softened water
Clearances
§ 3" (7.62 cm) behind dispenser for electrical and optional drain connection.
§ 6" (15.3 cm) in front of dispenser for ventilation.
Electrical
§ 115V, 60 Hz, 1 phase, 5A, maximum fuse 15A
§ Connect to dedicated 15A circuit, fuse or breaker
§ Must be grounded - requires 3-prong outlet. Do not remove ground.
Refrigeration
WARNING!
Do not damage the refrigerant circuit. Refrigerant can cause personal injury and/or damage dispenser.
§ Refrigerant R134a – 5.0 ounces (142 grams)
Heat Rejection
§ 1700 BTU/hr (498 W)
14.55" (370 mm)
22.05" (560 mm)
33.50" (851 mm)
110 lb (50 kg)
Maximum*
100 F (38 C)
90 F (32.2 C)
70 psi
Undercounter Dispenser and Ice Machine 7UC100A/7UD100A
7UC100A
14.55" (370 mm)
22.05" (560 mm)
31.50" (800 mm)
110 lb (50 kg)
50 F (10 C)
40 F (4.5 C)
10 psi
55% at 78 F (25.5 C)
7UD100A
Minimum*
5