Troubleshooting; Technical Data - Klauke i-press mini MAP2L Instruction Manual

Table of Contents

Advertisement

Instruction Manual
MAP2L
5.

Troubleshooting

a.) Constant fl ashing/indicating of the light diode display (page I, pic 1.3) or the occurence of an acoustical warning
signal.
see table 1. If the failure can not be solved return the tool to the nearest service center (ASC).
b.) The tool loses oil.
Return the unit to the manufacturer. Do not open it and damage the seal of the tool.
c.) The red LED fl ashes 3x and simultaneously 3 acoustic warning signals occure (see table 1).
Serious fault! If this fault occures repeatedly return the unit to an Autorized Service Center (ASC). Do not open
it and damage the seal of the tool.
In case of a one time occurence the fi tting has to be dismantled or pressed a second time.
6.

Technical Data

Type
Weight incl. battery:
Pressing time:
Thrust force (linear):
Battery voltage:
Battery capacity:
Battery charging time:
Cycles/charge:
Ambient temperature:
Hydraulic oil:
Sound level:
Vibrations:
HE.13112_A © 08/2009
MAP2L
1,7 kg
3-4 s
15 kN min.
18 V
1,5 Ah Li-Ion (RAL1/BL1815) or 3,0 Ah Li-Ion (RAL2/BL1830)
15 min. (RAL1/BL1815) or 22 min. (RAL2/BL1830)
approx. 150 cycles at NW 20 (RAL1/BL1815)
approx. 300 cycles at NW 20 (RAL2/BL1830)
-20°C to +40°C
Rivolta S.B.H. 11
70,6 dB (A) in a distance of 1m
< 2,5 m/s²
8