Chapter 2 Useful Features
Option
BMC IRQ
Post Error Pause
Memory Error
Power Switch Inhibit
CLI SETUP
Parameter
to start the OS. During this process, POST is suspended until
user interruption occurs.
[Disabled]
Specifies whether to allocate interrupt lines for BMC.
IRQ 11
Disabled
Enables or disables the feature to suppress OS boot process
until user interruption occurs when POST detects an error. If this
[Enabled]
option is set to [Disabled], the system attempts to start the OS
without waiting for user interruption, even if POST detects an
error.
Halt
Enables or disables the feature to suppress OS boot process
until user interruption occurs when POST detects degradation
[Boot]
error occurred on memory resources. This feature is enabled if
POST Error Pause is set to Enabled.
Even if this option is set to Boot, operation stops at the end of
POST if errors occurred for all resources.
[Disabled]
Enables or disables the power switch inhibit feature.
Enabled
[Disabled]
Enables or disables the Command Line Interface SETUP
feature. When this option is set to Enabled, the operation of
Enabled
SETUP is changed to use Command Line Interface (CLI). To
switch back to the menu operation, set this option to Disabled.
For details of the command, run HELP command after prompt of
CLI SETUP is displayed.
If the number of bootable devices exceeds a certain number, a
message "Failed to get Boot Variable data" is displayed on the
command line, and you are unable to open or change the Boot
menu. Reduce the number of bootable devices by
disconnecting unused USB device, or change Option ROM
Scan for onboard devices or PCI slots to Disabled.
Express5800/B120g-h Maintenance Guide
1. System BIOS
Description
[ ]: Factory setting