Chapter 3 Appendix
BMC Message on Lower LCD Line
CPU2_DIMMX Uncorrectable Error
(X: number)
ProcessorX Internal Error (X: 1 or 2)
Sensor Failure Detected.
SMI timeout
IPMI Watchdog timer timeout
IPMI Watchdog timer timeout (Power
off)
Mezzanine Card1 Power Fault
Mezzanine Card2 Power Fault
Drive X Fault (X: number)
E-Keying inconsistency Error (Not
Power ON)
Location Error (Not Power ON)
Node Manager Firmware Image
execution Failed
Node Manager Firmware Flash Erase
Error
Node Manager Firmware Flash
Corrupted
Node Manager Internal Error
Node Manager can't communicate
BMC
Node Manager Manufacturing Error
Node Manager Persistent Storage
Integrity Error
Cause
An uncorrectable error occurred
on DIMM for CPU #2.
X: Failed DIMM number (1-origin)
An internal CPU error (IERR)
occurred.
Abnormality in a sensor was
detected.
A timeout occurred while servicing
system management interrupts.
A watchdog timer timeout
occurred.
An error occurred on power supply
circuit of mezzanine card installed
in Type 1 mezzanine card slot of
CPU blade.
An error occurred on power supply
circuit of mezzanine card installed
in Type 2 mezzanine card slot of
CPU blade.
A failure was detected on SSD
installed in CPU blade.
X: SSD slot number (0-origin)
An unconformity of interface signal
was detected and the CPU blade
failed to power on.
In the Blade Enclosure,
combination of installation
locations of CPU blade,
mezzanine card, and switch
module is not correct.
The CPU blade failed to power on.
In the Blade Enclosure, the
installation location of CPU blade
is incorrect, or the installation
locations of the fan unit and CPU
blade are incorrect.
Abnormality in Node Manager
occurred.
Express5800/B120g-h Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Contact your sales representative.
Check installation status of the failed
mezzanine card.
Contact your sales representative.
Refer to the User's Guide of the Blade
Enclosure to make sure that the CPU
blade and switch module are installed in
correct locations.
Refer to the User's Guide of the Blade
Enclosure to make sure that the CPU
blade is installed in correct locations.
Check if the fan units and CPU blades
are installed in correct locations.
Turn off the power, wait for at least 30
seconds, and restart the server.