ADSL2+ Tester
•
Switch off the instrument.
•
Connect RS232 communication cable between the integrated RS232 port with the
serial port of your PC.
•
Switch on the instrument and set RS232 "Port State" as "ON".
•
Click "Select" icon in the short-cut bar or in the "Manipulation" menu to choose the
type of instrument which you are working with.
•
Click "Connect" icon in the short-cut bar or in the "System" menu to make the
connection with the instrument.
•
After connecting successfully, user can do the operations as below.
ü
Upload the stored results:
Click "Upload" icon in the short-cut bar or in the "Manipulation" menu to upload
the stored results from the instrument.
ü
View the uploaded results:
Click "View" icon in the short-cut bar or in the "Manipulation" menu to check the
detailed information of every uploaded results in the software. If there has a
graph result, user can also view the histogram analysis of the error and alarm
events. In addition, user can delete and print any result.
ü
Clean up all uploaded results in software:
Click "Clean Up the Records" the "System" menu to delete all the uploaded
results of one instrument in the list.
ü
Upgrade the embedded software:
Click "Upgrade embedded software" the "System" menu to update the
embedded software of the selected instrument.
First step: Click "Read" button to read out the type and software version of the
selected instrument.
Second step: Click "Load File" button to load the target hex file into the
program.
Third step: Click "Next" button to enter into the upgrading window and then click
"Upgrade" button to start upgrading.
Fourth step: The program will automatically complete the upgrading process.
After being upgraded, the instrument will reset itself.
Fifth step: Switch off the instrument and uninstall the RS232 communication
cable. Close "TestManagerPro" program.