ADSL2+ Tester
"Low Battery" Indication
n
When being powered by the battery, this tester can give the early alarm to low battery
voltage and the "Low Battery" indicator turns on. After being used for a couple of hours,
the battery voltage continues to drop to a low level, and the tester will automatically
perform protective shutdown. When the "Low Battery" indicator turns on, the external
power supply is needed to support the tester working while the battery is charging.

3.7 Power Management

This tester provides automatic power-off function. When the tester is not under test-started
status and there is no keystroke in 5 minutes, this tester will be turned off automatically.
This function can effectively prevent the tester from being accidentally turned on and the
battery from being exhausted during the transport. This function can be set to
"Others" menu.
The LCD backlight can be turned on by pressing the "Backlight" key, and be automatically
turned off in 30 seconds. This function can be set to
as OFF, press the "Backlight" key to turn on the backlight, and press the "Backlight" key
again to turn off the backlight.

3.8 Safety Precautions

The following general safety precautions must be observed during all phases of operation,
service, and repair of this instrument. Failure to comply with these precautions or with
specific warnings elsewhere in this manual violates safety standards of design, manufacture,
and intended use of the instrument. The manufacturing company assumes no liability for
the customers' failure to comply with these requirements.
Warning:
Do not operate damaged equipment: Whatever it is possible that the safety
protection features built into this product have been impaired, either through
physical damage, excessive moisture, or any other reason, remove power and
do not use the product until safe operation can be verified by service-trained
personnel. If necessary, return the product to your vendor and service office
for service and repair to ensure the safety features are maintained.
3.8.1
External Power Requirements
Please use the supplied AC adapter when operating with the instrument or charging the
battery. The supplied AC power adapter requires a power source of 100V to 240V AC at a
frequency between 50Hz and 60Hz (nominal).
AC Input: 100V ~ 240V, 50/60 Hz, Max 0.45A.
The AC adapter will output a DC power of 12V to the instrument.
72-0046-03A
ON
or
OFF
in "Others" menu. When set
3 Manipulation
ON
or
OFF
in
20