Design Guide
THE INSTALLATION
SPACE
36" Models12"
42" Models18"
48" Models20"
_
_Finished
Width_
J
AreaElectdc X15 l
84 1/2"
max,
,
^
J
L'"
831/2,,
min II
Finished ][
Opening ] [
75"FromFloor
[_5
to Bottom
24"
ff Electrical
Area
WaterSupply_ 5%
/
I)
3i/2"
*The
finished
cutout
width
must
be:
35-1/2"
fin" 36" models
41-1/2"
for 42" models
47-1/2"
fin" 48" models
Water
And Electrical
Locations
The opening
must be prepared
with the electrical
and water
supply
located
as shown.
The
cutout
depth
must
be 24"
The refrigerator
will project
fin'ward,
slightly
beyond
ac!jacent
cabinetry;
depending
on wmr installation.
Cutout
depth
beneath
a soffit:
When
installed
beneath
a soffit, the soffit cannot
exceed
the 24" installation
depth
shown.
The
top case
trim
overlaps
the bottom
of the soffit.
Additional
Specifications
• A 115 volt 60Hz.,
15 or 20 amp power suI}ply is
required.
An
individual
properly
grounded
bran(h
circuit
or circuit
breaker
is recommended.
Install
a propedy
grom_ded
3-prong
electrical
receptacle
recessed
into
the back wall. Electrical
must
be
located
on rear wall as shown.
NOTE: OF] (grotmd
fault interrupter)
is not
recoi/lillended.
• _&_ter line can enter
the opening
through
the floor
or back wall. The water line should
be 1/4"
O.D.
copper
tubing
or GE SmartConnect'"
kit between
the cold water
line and water
connection
location,
long enough
to extend
to the front
of the
refrigerator.
Installation
of an easily accessible
shut
off wflve in the water
line is required.
DIMENSIONS
AND CLEARANCES
_83-1/
at
Real
25-3/8" FramedModels
25-3/4" StainlessSteelModels
_84" From
Floorto
TopFrame
Shippingheight.The
refrigeratorcan be
adjustedto fit into a
cutoutthat is 83-1/2"
min. to 84-1/2"max.
height. Note that the
top casetrim at the
front is 1/2" higher
andwill overlap
uppercabinetryor
soffit. Useleveling
legs andwheels for a
maximum1" height
adjustment.
.36", 42", or 48"
Frame to Frame
DepthIncludingHandles:
26-7/8" FramedModels
27-3/4" StainlessSteelModels
Product
Clearances
These
refi'igerators
are equipi)ed
with a 2 position
door
stop. The thctorv
set 130 ° door swing can be
ac!justed
to 90 ° if clearance
to ac!jacent
cabinets
or
walls is restricted.
130° DoorSwing
_'-4. . .... /
,...
.)_
90° DoorSwing
i
T
23-7/8"
Behind
Frame
Models
A
B
C
36"
13"
15"
20-5/8"
42"
13"
19"
26-5/8"
48"
15"
20"
28-5/8"
4" Min.
to Wall
Allow
minimmn
clearances
fin" fl'eezer
door
(Dimension
A) and
fl'esh
fi_od
door
(Dimension
B)
fl)r a flfll
130 ° door
swing
and
to allow
fl_r pan
YeIlloval.
4" minimmn
clearance
is required
when
door
swing
is ac!justed
to 90 °. If the 90 ° door stop position
is
used, pan access
is maintained,
but pan
remowfl
is
restricted.
See illustrations
pages
4 and
5 to determine
door
swing
interaction
with
ac!jacent
cabinets
or
COtlntertol)
s.