Installation And Adjustment; Parameters; Uty Cycle - Matco Tools M148 Operator's Manual

M series inverter mig welding machine
Table of Contents

Advertisement

§3 Installation and Adjustment
§3.1 Parameters
Model

Parameters

Input Voltage
(V)
Input Current
(A)
Input Power
(KW)
Welding
Current(A)
No-load
Voltage(V)
Duty cycle
(40℃)
Diameter(mm)
Protection
class
Insulation
class
Dimensions
(mm)
Weight
(Kg)
Note: The above parameters are subject to chan.
§3.2 Duty cycle and Over-temp
The rated duty cycle is defined as the proportion of the time that a machine can work
continuously over a 10 minute cycle when set at 100% of rated output welding current in 40C
(104F) ambient environment.
When the transformer reaches an over-heat condition, the heat sensor inside it will open and
will output an instruction to circuit board to cut AC relay and the output welding current while
illuminating the over-heat pilot lamp in the front panel. At this time, all welding operations should
cease for 15 minutes allowing the cooling fan to reduce the temperature. The unit will auto-reset
when correct temperature has been achieved and pilot light will go out. If the machine reached
the over-temp capacity again, the welding output current or the arc cycle should be reduced.

INSTALLATION AND ADJUSTMENT

M148 (110VAC)
1~110/115±10%
20 (max.)
4.2
35~140
48
40%130A 100%95A
Fe:0.6/0.8/0.9 SS: 0.6/0.8/0.9 Flux-Cored:0.8/0.9/1.0
465*214*395
M208 (220VAC)
25%200A 100%120A
IP23
H
12.5 Kg.
9
1~208-240±5%
20 (max.)
5.7
50~200
57
465*214*395

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M208

Table of Contents