Ac Input Wiring Motor Output Wiring; Plus Gnd 3W Plus Gnd; Wiring: 200–250 V Three-Phase Fan Controllers - BIG ASS FANS Pivot Installation Manual

Hide thumbs Also See for Pivot:
Table of Contents

Advertisement

Wiring: 200-250 V, three-phase fan controllers
WARNING: Wait three minutes after disconnecting before servicing!
WARNING: Improper installation can cause electric shock or damage to the motor and controller. A
qualified electrician should perform the installation.
The diagrams below show wiring options for a 200-250 V, 3 Φ fan controller. See "Power Requirements for Fan
Controllers" for detailed power requirements.
Wiring for 200-250 V, 3 Φ, 50/60 Hz fan controllers
A disconnect is included with the fan controller for
200-250 V, 3 Φ. An EMI filter is not included with this
fan controller.
Note: This fan controller does not contain fusing!
Power must be supplied to this controller via
a dedicated circuit breaker or properly fused
disconnect!
Optional 1 Φ wiring for 200-250 V, 3 Φ, 50/60 Hz
controllers
The L3 terminal is not used when wiring the fan
controller for 200-250 V, 1 Φ. A disconnect is included
with the fan controller. An EMI filter is not included with
this fan controller.
Note: This fan controller does not contain fusing!
Power must be supplied to this controller via
a dedicated circuit breaker or properly fused
disconnect!
30
WWW.BIGASSSOLUTIONS.COM
© 2015 DELTA T CORP.
1 2 5 6
1 2 5 6
25 4 11
25 4 11
U
V
W
/T1
/T2
/T3
GRN/YEL
BLK
RED BLU
1 2 5 6
25 4 11
1 2 5 6
25 4 11
U
V
W
/T1
/T2
/T3
BLK
GRN/YEL
RED
AC Input Wiring
Motor Output Wiring
2W plus GND
ALL RIGHTS RESERVED.
13A13B13C 14 30 16 17
L1
L2
L3
L3
RED
GRN/
BLK
BLU
13A13B13C 14 30 16 17
L1
L2
L3
RED
GRN/
YEL
BLK
BLU
3W plus GND

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents