AMX DCE-1 Instruction Manual page 19

Display control and edid manager
Table of Contents

Advertisement

API Command List Instructions (cont.)
IDX
Function Description
15
SET RELAY To
Momentary
16
GET RELAY Momentary
17
Set VP cooling time
18
Get VP cooling time
19
Set the video on mode
for the video output port
20
Get the video on mode
status for the video
output port
Instruction Manual - Display Control and EDID Manager
Command
Command:
CMD#T
Return:
CMD#T
Description:
MD# : # = {1 ~10 (seconds)}
Command:
SMDT
Return:
SMDT( value )
Description:
value = {1 ~10 (seconds)}
Command:
CVPD#T
Return:
CVPD#T
Description:
MD# : # = {0~5 (seconds)}
Command:
SVPDT
Return:
SVPDT(value)
Description:
value = {0 ~5 (seconds)}
Command:
CVON#T
Return:
CVON#T
Description:
# = {0 ~1}
0: OFF
1: ON
Command:
SVONT
Return:
SVONT(#)
Description:
# = {0 ~1}
0: DISABLE
1: ENABLE
API Command List Instructions
Example
Command:
CMD2T
Return:
CMD2T
Description:
Set relay momentary hold time as 2
seconds.
Command:
SMDT
Return:
SMDT(2)
Description:
Get relay momentary hold time, the
result is 2 seconds.
Command:
CVPD2T
Return:
CVPD2T
Description:
Set VP cooling time to 2s.
Command:
SVPDT
Return:
SVPDT(2)
Description:
Get VP cooling time, the result is 2s.
Command:
CVON0T
Return:
CVON0T
Description:
Set video on mode as disabled.
Command:
SVONT
Return:
SVONT(0)
Description:
Video on mode is disabled.
Note
Default setting
is 3s.
Default setting
is 0s.
19