Trotec DS Series Original Instructions Manual

External condensate pump

Advertisement

Quick Links

External condensate pump
DS/DH series
EN
ORIGINAL INSTRUCTIONS
EXTERNAL CONDENSATE PUMP

Advertisement

Table of Contents
loading

Summary of Contents for Trotec DS Series

  • Page 1 External condensate pump DS/DH series ORIGINAL INSTRUCTIONS EXTERNAL CONDENSATE PUMP...
  • Page 2: Table Of Contents

    Notes regarding the instructions .......... 2 Safety .................. 2 Information about the device.......... 4 EKP DS-/DH-Serie Transport and storage............ 5 Assembly and installation............. 5 https://hub.trotec.com/?id=42513 Errors and faults.............. 8 Safety Maintenance ................ 9 Read this manual carefully before starting or using the Technical annex.............. 10 device. Always store the manual in the immediate vicinity Disposal ................ 12...
  • Page 3 • Ensure that all electric cables outside of the device are • Any operation other than as described in this manual is protected from damage (e.g. caused by animals). Never prohibited. Non-observance renders all claims for liability use the device if electric cables or the power connection and guarantee null and void.
  • Page 4: Information About The Device

    With its robust and corrosion-resistant housing it is particularly suited for combination with the pool dehumidifiers of Trotec's DS and DH series, but can also be used with other dehumidifiers without a hitch.
  • Page 5: Transport And Storage

    Transport and storage Assembly and installation Note Scope of delivery If you store or transport the device improperly, the • 1 x Device device may be damaged. • 2 x Hose Note the information regarding transport and storage of • 2 x Hose clamp the device.
  • Page 6 Wall mounting (optional) Mains supply of the dehumidifier Assemble the device as follows: Warning of electrical voltage 1. Mark the positions for the bore holes on the wall. Work on the electrical components must only be 2. Drill the holes into the wall at the marked positions. carried out by an authorised specialist company! 3.
  • Page 7 5. Observe the dehumidifier's technical data and use the 10. Then fit the housing cover (1) and secure it with the suitable connection plug. screw (9). ð white connection plug for 230 V. ð black connection plug for >230 V (potential-free contact). Hose connections 1.
  • Page 8: Errors And Faults

    Warning of electrical voltage • If the device is not starting, have the electrics checked by Do not touch the mains plug with wet or damp hands. a specialist company or by Trotec. Note The pump does not operate: When switching the dehumidifier off, wait for approx.
  • Page 9: Maintenance

    Thorough cleaning Maintenance Perform this activity at least once a year. 1. Remove the hose lines at the discharge hose (8) and feed Activities required before starting maintenance hose (10) connections. Warning of electrical voltage Do not touch the mains plug with wet or damp hands. •...
  • Page 10: Technical Annex

    6. Open the hooks on the right- and left-hand side that Technical annex connect the lower container and the upper part of the pump. Technical data Parameter Value Model External condensate pump DS/DH series Article number 6.100.000.019 Feed hose connection Ø 1/2 inch* Discharge hose connection Ø...
  • Page 11 Wiring diagram -X1 1.1 -X1 1.2 -X1 1.3 -X1 1.4 -X1 2.1 -X1 2.2 -X1 2.3 -X1 3.1 -X1 3.2 -X1 3.3 -X1 3.4 230 VAC / 6.0 A PE.1 PE.2 DS/DH series...
  • Page 12: Disposal

    Disposal The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity.
  • Page 13 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...