Information marked with this symbol helps you to carry out your tasks quickly and safely. Follow the manual Information marked with this symbol indicates that the operating manual must be observed. Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
Hold onto the mains plug while doing so. • Observe the storage and operating conditions (see chapter Technical data). Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
Page 4
• Before performing any work on the device, in case of leaks in the water system, before taking work breaks or when not in use, remove the mains plug from the mains socket. Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
Page 5
Non-observance renders all claims for liability and guarantee null and void. Dip the pump into the water at a slight angle to allow the remaining air to escape Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
Allow the device to cool down and switch it off. Investigate the cause of overheating. Should the problem persist, please contact the customer service. Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
2. Completely remove the packaging. 3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding. Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
Page 9
3. Put the seal ring (11) onto the retainer (10) including backflow preventer (9). The profiled side rests on the retainer (10). 7. Affix the hose by means of the hose clamp. Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
Page 10
1. If required, lock the float switch (4) in the desired position by pushing the cable into the float switch locking device (3) at the side of the pump. Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
Page 11
5 mm. Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
ð The device will be switched off as soon as the float switch (4) reaches the set or the minimum switch-off height. ð With the float switch affixed in this position, the device is switched on permanently. Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
• Check whether the hose line is kinked or blocked. Remove kinks and / or blockages. • Check whether the reducer (7), the backflow preventer (9) and / or the elbow (8) are blocked. Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...
Your device still does not operate correctly after these checks? Please contact the customer service. If necessary, bring the device to an authorized specialist electrical company or to Trotec for repair. Operating manual – submerged clear water pump, near-ground suction TWP 4005 E...