Transmitter Mag 6000 - Siemens SITRANS F M MAGFLO Operating Manual

Electromagnetic flowmeters transmitter type mag 6000 19" & safety barrier [eex ia/ib] iib sensor type mag 1100 ex & mag 3100 ex
Hide thumbs Also See for SITRANS F M MAGFLO:
Table of Contents

Advertisement

® ® ® ® ®
SITRANS F M MAGFLO
4.3 Transmitter
MAG 6000
Accuracy 0.25%
4. Technical data
Current output
Current
Load
Time constant
Digital output
Frequency
Time constant
Active
Passive
Relay
Time constant
Load
Digital input
Activation time
Current
Functions
Galvanic isolation
Cut-off
Low flow
Empty pipe
Totalizer
Display
Time constant
Zero point adjustment
Electrode input impedance
Excitation frequency
Ambient temperature
Custody transfer approval
MAG 6000 CT
Communication
Standard
Optional
19" insert
Enclosure material
Enclosure rating
Mechanical load
EMC performance
Supply voltage
Power consumption
1
) Special cable required in separate mounted installation
SFIDK.PS.026.C2.02
0-20 mA, 4-20 mA or 4-20 mA + alarm
< 800 ohm
0.1-30 s adjustable
0-10 kHz, 50% duty cycle
0.1-30 s adjustable
24 V DC, 30 mA, 1 KΩ ≤ R
load
3-30 V DC, max. 110 mA, 200 Ω ≤ R
Changeover relay, time constant same as current time constant
42 V AC/2 A, 24 V DC/1A
11-30 V DC, R
= 4.4 KΩ
i
50 ms
I
= 2.5 mA, I
= 7 mA
11 V DC
30 V DC
Flow rate, 2 totalizers, low flow cut-off, empty pipe cut-off, flow
direction, error system, operating time, uni/bidirectional flow, limit
switches, pulse output, control for cleaning unit and batch
All inputs and outputs are galvanically isolated
0-9.9% of maximum flow
1
Detection of empty pipe
)
Two eight-digit counters for forward, net or reverse flow
Background illumination with alphanumerical text, 3 × 20 characters
to indicate flow rate, totalized values, settings and faults
Reverse flow indicated by negative sign
Time constant as current output time constant
Automatic
> 1 x 10
14
Sensor size depending pulsating DC current (125 mA)
Display version during operation: −20 to +50°C
Blind version during operation: −20 to +60°C
During storage: −40 to +70°C (RH max. 95%)
PTB
DANAK OIML R75
(cold water)
(hot water)
6.221
99.19
Prepared for client mounted add-on modules
HART, Profibus PA as add-on module
Standard 19" insert of aluminium/steel (DIN 41494)
Width: 21 TE
Height: 3 HE
IP 20 to EN 60529 and DIN 40050
Version: 1 G, 1-800 Hz sinusoidal in all directions to EN 60068-2-36
Emission: EN 50081-1 (Light industry)
Immunity: EN 50082-2 (Industry)
115-230 V AC +10% to −15%, 50-60 Hz
11-30 V DC or 11-24 V AC
230 V AC: 17 VA
24 V DC: 9 W, I
= 380 mA, I
N
ST
12 V DC: 11 W, I
= 920 mA, I
N
ST
≤ 10 KΩ, short-circuit-protected
≤ 10 KΩ
load
DANAK OIML R117
(cold water/milk, beer etc.)
= 8A (30 ms)
= 4A (250 ms)
17