Auto Cleaning Output Measurement/Setting (462) - FujiFilm FRONTIER 350 Instruction Manual

Digital minilab manager printer controller
Table of Contents

Advertisement

distributed by www.minilablaser.com
9.2.22 Auto Cleaning Output
Measurement/Setting (462)
[Selection]
"4 Setup and Maintenance" - "6 Processor
Adjustment/Maintenance" - "2 Auto Cleaning
Output Measurement/Setting"
[Procedure]
Confirm discharging process of the auto cleaning
pump.
1
Click the [Start] button for "No.2".
• The following display appears on the operation
panel.
# No.2 MEASURE
# START
2
Press the [Enter] key on the printer operation
panel.
• The auto cleaning pump starts to discharge after
countdown of ten seconds.
[YES] ?
3
Open the dryer unit and support it with Stopper 2
(yellow).
4
Remove the No.2 crossover rack and make sure
it is wet completely with cleaning water.
5
Reinstall the No.2 crossover rack.
6
Close the dryer unit.
7
Repeat Steps 1 though 3 for "No.3".
8
Remove the No. 3 crossover rack and make sure
it is wet completely with cleaning water.
9
Reinstall the No.3 crossover rack.
10
Repeat Steps 1 through 3 for "Dryer entrance
rack".
FMPC
Stopper 2 (Yellow)
L2259
No.2 Crossover Rack
No.3 Crossover Rack
L21121
131