8.2.25 Processing Temperature Setting
(463)
[Selection]
"4 Setup and Maintenance" - "6 Processor
Adjustment/Maintenance" - "3 Processing
Temperature Setting"
[Procedure]
Set the processing temperatures.
1
Enter the numerical values of the "P1", "P2" and
"PS" processing temperatures.
Range
P1
30.0 to 40.0
P2
30.0 to 40.0
PS
30.0 to 40.0
2
Click [OK].
• Operation returns to the "4 Setup and
Maintenance" screen.

8.2.26 Replenisher Rate Setup (464)

[Selection]
"4 Setup and Maintenance" - "6 Processor
Adjustment/Maintenance" - "4 Replenisher Rate
Setting"
[Procedure]
Set the replenishment amount.
1
Default Value
38.5
38.0
38.0
2
• Operation returns to the "4 Setup and
Enter the numerical values of the "P1-R", "P2-R"
and "PS-R" replenishment amount.
Range
P1-R
30.0 to 200.0
P2-R
20.0 to 300.0
PS-R
100.0 to 300.0
Click [OK].
Maintenance" screen.
FMPC
Default Value
45.0
35.0
150.0