Other - HIOS HSF-10 Instruction Manual

Hsf series, automatic screw feeder
Table of Contents

Advertisement

7. Other

Overload protection circuits
This device includes overload protection circuits.
Under ordinary operation, the drive motor rotates correctly (ordinary rotation), transporting screws to the rail section, enabling
screws to be taken out continuously. However if the drive sections become overloaded, the drive motor rotates in the reverse
direction briefly, followed by correct rotation.
If the cause of the overload disappears during reverse rotation, the device will return to the correct rotation allow screws to be taken
out continuously. If the cause of the overload does not disappear, a series of reverse rotation, correct rotation, reverse rotation,
correct rotation will continue for a set amount of time before power to the drive motor is cut.
If power has been cut to the drive motor, turn the power switch OFF and remove the cause of the overload.
For example, if there are too many screws in the panning area, remove some of the screws to achieve the appropriate level. If
screws are jammed in the drive parts, remove those screws.
Turn the power switch ON after the cause of the overload has been removed, and use the device as per normal (power reset).
If you need to replace AC adapter of HSF screw feeder
If you need to replace AC adapter of HSF screw feeder, attach the Ferrite core like below, taking out it from the old one.
Insert the AC cable like the picture.
Ferrite core
Connector
about 10cm
If you do not have it then please get it from the market; GRFC-6* of KGS or equivalent.
* https://www.techno-kitagawa.com/content/download/1358/14620/file/GRFC_shohin3.pdf