RAID Scanning
RAID Scanning:
Click Modify Settings
to change settings.
TeraStation User Manual
RAID Scanning is the feature to read check for all sectors in the data area of hard
drives which build RAID 1, 5 and 10.
An error possible to repaired* (bad sectors) which is found during check will be
automatically repaired.
Also an error possible to repaired* which is found during standard file operations will
be automatically repaired regardless of performing RAID Scanning or not.
Status
Descriptions
Recoverable errors*
• Read error in the data area which are build in RAID 1, 5, or
10 (including RAID 1 system area)
Unrecoverable errors • Write Error
• RAID management area error
• Drive partition information area error
• Drive recognition failure, etc.
If many errors possible to repair *(bad cluster) are found in one of the hard drives
which build RAID, that drive will be removed and the system will automatically move
to degrade mode.
Data are not protected in the degrade mode, it is strongly recommended to
immediately replace the erroneous hard drive.
When running RAID Scanning in the first time, it is strongly recommended to backup
data on the TeraStation in advance.
RAID Scanning:
Set whether using RAID Scanning or not.
RAID Scanning Schedule:
Select the schedule to perform RAID Scanning.
• Every Week, and from Sunday to Saturday
• 1st, and from Sunday to Saturday
• 2nd, and from Sunday to Saturday
• 3rd, and from Sunday to Saturday
• 4th, and from Sunday to Saturday
• 1st, 3rd, and from Sunday to Saturday
• 2nd, 4th, and from Sunday to Saturday
• Every 1st day/month
Select Begin Immediate RAID Scan and click Save to immediately run the maintenance.
RAID Scanning Start Time:
Select time to start RAID Scanning from 0 to 23 o'clock.
* To stop RAID Scanning, click Abort RAID Scanning.