Installing Countertop Dispensers With Bottom Exiting Utilities - Follett Symphony Plus 25 Series Installation, Operation And Service Manual

Ice and water dispensers
Hide thumbs Also See for Symphony Plus 25 Series:
Table of Contents

Advertisement

Installing countertop dispensers with bottom
exiting utilities
WARNING!
§ A sturdy work surface capable of supporting the
entire dispenser must be used.
§ The work surface must be large enough to
accommodate height of dispenser.
§ Failure to provide proper support may result in
personal injury.
1. Position dispenser with dispense chutes facing
upward on sturdy work surface (Fig. 3).
2. Move drain fitting from back of dispenser and
mount (Fig. 4.1).
3. Cut drain tube to length and attach to barbed
connection (Fig. 4.2).
4. Move inlet water fitting from back of dispenser
and mount (Fig. 4.3).
5. Cut water tubing to length and re-insert into
water fitting.
6. Remove the drain plug from the internal drain
line connection point and relocate to back of
dispenser and reconnect.
7. Raise the dispenser upright and position in
desired location.
8. Mark dispenser outline on counter and remove
dispenser.
9. Cut countertop utility opening and drill four
7/16" holes to anchor dispenser to counter
(Fig. 5).
10. Apply a thick bead approximately 1/4" (7 mm)
diameter of NSF-listed silicone sealant (Dow
Corning* RTV-732 or equivalent) 1/4" (7 mm)
inside marked outline of dispenser.
11. Reposition dispenser on counter and secure to
counter with four 3/8"-16NC bolts.
12. Smooth excess sealant around outside of
dispenser and make utility connections
through countertop cutout.
13. Turn on water supply and check for leaks.
14. Clean dispenser and ice machine.
15. Turn power on and allow ice machine to
produce ice.
Fig. 3
Fig. 4
2
TRIM DRAIN TUBE FOR
NEW DRAIN FITTING
LOCATION.
5
Fig. 5
(53.3 cm)
4X
Ø.375"
1.56"
(10 mm)
(4.0 cm)
hole
14.00"
(35.6 cm)
16.00"
(40.7 cm)
C/E25CI425A, C/E50CI425A
5.00"
(12.7 cm)
min.
3
1
21.00"
0.50"
(13 mm)
20.00"
(50.8 cm)
1.56"
(4.0 cm)
2.50"
(6.36 cm)
Cutout
connections
12.50"
through
(31.8 cm)
bottom
(17.8 cm)
16.50"
(41.9 cm)
7.00"
7