Yaesu FT-1000MP Operating Manual page 89

Hide thumbs Also See for FT-1000MP:
Table of Contents

Advertisement

Menu Programming
-
Selection &
Settings
Memory Scan Skip
-
Enable/disable the
memory scan skip feature. When OFF, memories
marked for scan skip will be passed over during
scanning. When ON, all memories are scanned.
Scan Delay Time
-
Select a scanning delay
time of
1
-
10 seconds. This determines how long
scanning pauses on activity before resuming.
Notch Operation
-
Selects Notch Filter opera-
tion:
IF NOTCH
-
Manual IF notch operation using
the front panel knob with the same name.
AU7"0 DSP
-
When the
NOTCH
button is
pressed, the EDSP multiple notch circuit automat-
ically locates existing heterodynes and notches
them. Any additional heterodynes are also
notched as they appear.
SELECT
-
The EDSP button selects notch
operation. If EDSP is active and the
NOTCH
button
is pressed, Auto-Notch operation takes effect.
With EDSP disabled, manual notch operation is
activated.
Frequency Display Format
Carrier
-
Display the actual carrier frequency,
'
without any offset added. When changing modes,
the frequency display remains constant.
Offset - When changing modes, the frequency
display changes to reflect the added BFO offset.
Display Resolution
-
Select 10 Hz, 100 Hz, or
1 kHz display frequency resolution for the main
and sub-VFO displays. Note that this setting does
not affect tuning step size.
Expanded Tuning Scale
-
Selects the display
format of the expanded tuning scale located
above the main frequency display:
Dial
-
Permits sub-resolution tuning and dis-
play using small sub-increment segments that
expand outward as the dial is turned.
Clarifier - permits viewing relative Rx or
Tx
clarifier offset from the displayed frequency. A
single segment moves left or right from center as
the
GLAR
knob is rotated.
Transverter Display
-
Select 50, 144, or 430
offset to be displayed in the 1 's, 1 o's, and 100's of
MHz place for operation with a transverter.
LCD Display Brightness
-
Enables adjusting
the display intensity between high or low.
Panel Offset Diisplay Mode
-
Select one or
four parameters to be viewed in the smaller sub-
display to the right of the MAlN VFO-A frequency
display:
Clarifier
-
Display "clarified" frequency offset
AFrx or AFtx from original frequency.
Channel Freq.
-
Display the operating fre-
quency contained in the selected memory chan-
nel.
Offset
-
Displays the frequency difference (off-
set) between the displayed MAlN VFO-A and
SklB VFO-B frequencies.
A1 (CW) Pitch
-
Displays the default CW pitch
setting.
Sub-Meter Bar Graph
-
Enables the S-meter
bargraph segment display for SUB VFO-B
Main Meter Peak-Hold
-
Enableldisable peak-
hold feature, and select display badsegment per-
sistence (delay time) from 10
-
2000 msec.
Sub Meter Peak Hold
-
Enable/disable peak-
hold feature, and select display barlsegment per-
sistence (delay time) from 10
-
2000 msec.
RF Power Output Range
-
Select a maximum
RF power output limit of 100W, SOW, or 1 OW.
page 87

Hide quick links:

Advertisement

Table of Contents
loading