Front Pane
i
EDSP
COKTOVR+NR
@
/
B
-
C
D
RX
TX
CLEAR
I
(34)
SUB
VFO-B
RX
& TX
LEDs
(38) C W and Electronic Keyer Controls
'SPOT
turns the CW receiver spotting heterodyne
oscillator on and off.
BK-IN
turns full break-in
(QSK) CW operation on and off.
KEVER
toggles
the internal CW keyer onloff, as indicated by the
LED above this button.The
SPEED
control is for
speed adjustment of the keyerlbug simulator.
These lamps select and indicate the current
status of SUB VFO-B. When the green
RX
lamp is
lit, the receiving frequency is under control of SUB
VFO-B. When the red
"h%
lamp is lit, the transmit-
ting frequency is under control of SUB VFO-8.
During dual receive operation, the green
RX
lamps above both tuning knobs are lit.
(39)
PITCH
Control
Rotate this to select your desired CW tone
pitch (from 300-1050 Hz, in 50 Hz increments),
as shown in the display. The Tx sidetone, re-
ceiver IF passband, and display offset from the
BFO (carrier) frequency are all affected.
(35)
SUB VFO-B
Tuning Knob
This knob adjusts the SUB VFO-B operating
frequency. Tuning increments are the same as
described for the main tuning knob.
(40)
CLAR
Pushbuttons
(36)
LOCK
This button toggles locking of SUB VFO-8 tun-
ing to prevent accidental frequency changes. The
red indicator in the display glows when active (the
knob can still be turned, but it does nothing).
Press the button again to re-enable the tuning
knob.
Pressing the
RX
button activates the
CLAR
knob, to allow offsetting the receiving frequency
temporarily (see item 41 below). The
TX
button
provides the same function for the transmit fre-
quency. If both buttons are pressed, the receiver
and transmitter are both offset from the original
frequency. Pressing the
CLEAR
button zeroes any
offset tuned by the
CLAW
knob. Each memory and
VFO retains all clarifier settings independently.
(37)
sue
so^
This separate control sets the signal level
threshold at which SUB VFO-B receiver audio is
muted (and the green
SUB BUSY
display indicator
turns off), in all modes. This control is normally
kept fully CCW, except when scanning and during
FM operation.
(41)
CLAR
This knob tunes the clarifier ofFset frequency
up to 9.99 kHz when activated by the
CLAR W X TX
buttons just below it (the 3-digit display appears in
the center of the display (if enabled) when the
clarifier is active).