  • Page 1 ® NIMBUS PEDIATRIC STSTEM Instructions For Use Product Photo...
  • Page 3: Table Of Contents

    Nimbus Pediatric System........
  • Page 4 (ii)
  • Page 5: General Safety

    • The cover of this product is vapour permeable but not air permeable and may present a suffocation risk. • Only the pump and mattress combination as indicated by ArjoHuntleigh should be used. The correct function of the product cannot be guaranteed if incorrect pump and mattress combinations are used.
  • Page 6 Design Policy and Copyright ® and ™ are trademarks belonging to the ArjoHuntleigh group of companies. As our policy is one of continuous improvement, we reserve the right to modify designs without prior notice.
  • Page 7: Introduction

    The mattress replacement is designed for use with the ArjoHuntleigh ChildMinder or Hi-Lo Crib. Users are able to employ established practices for moving and handling patients. A water resistant, vapor permeable cover is supplied...
  • Page 8: Clinical Applications

    2. Clinical Applications Indications The systems are indicated for the Nimbus Pediatric prevention and management of all categories of pressure ulcer when combined with an individualised monitoring, repositioning and wound care programme. mattress is designed for patients Nimbus Pediatric weighing between 13 - 55 lb (6 - 25 kg).
  • Page 9: Product Description

    3. Product Description Mattress mattress replacement is Nimbus Pediatric comprised of a series of 18 individual cells, all of which inflate alternately. The best way of describing cell arrangement is that, if all cells were numbered 1 to 18, the odd number cells inflate simultaneously while the even number cells are deflated and then vice versa.
  • Page 10: Pump

    At the foot end of the mattress replacement a tube-set serves to inflate and deflate the Nimbus Pediatric mattress replacement. To deflate the mattress replacement quickly in the event of cardiac arrest pull the CPR Tag firmly to remove the CPR plugs.
  • Page 11 The pump can be fixed to the foot end of the Bed Bracket ArjoHuntleigh ChildMinder or Hi-Lo Crib by the separate crib bracket which has been designed for simplicity and ease of use. It features a simple self...
  • Page 12: Installation

    Section 5. Preparing the Pump and Mattress Replacement 1. Remove the pump from the carton together with the Installing the Nimbus Pediatric Pump mattress replacement and cover. You should have the following items: •...
  • Page 13 5. Ensure individual cells of the Nimbus Pediatric mattress replacement are uppermost. 6. Secure the mattress replacement Nimbus Pediatric by fixing the six straps (three at each end) to the moveable part of the crib base. 7. Place the protective cover on the mattress replacement and fix into position with the zips and velcro provided.
  • Page 14: Connecting The Tubeset

    Connecting the To connect the tubeset to the mattress and pump: Tubeset 1. Locate the bottom of the tubeset connector onto the bottom of the pump/mattress connector. 2. Pull the top of the tubeset connector up and over the top of the pump/mattress connector, until the tubeset connector “clicks”...
  • Page 15: Inflating The Mattress

    Inflating the Mattress 1. Insert the power plug into the power socket. 2. Switch the pump switch to ON; the ON/OFF light on the front panel should illuminate. 3. The pump will now run a self test for approximately 3 seconds when all lights will be illuminated.
  • Page 16: Deflating The Mattress

    5. Retest the alarm after at least 4 hours. Allow the alarm to operate for 2 minutes to ensure that it has been adequately recharged. 6. If the alarm does not operate for 2 minutes, call the service engineer. Continue to use the pump only under supervision to ensure that the power-on status is checked at regular intervals All other alarms will continue to function as normal.
  • Page 17: Operation

    System Optimization The System automatically Nimbus Pediatric compensates for patient weight distribution and position, optimizing the pressure relieving performance. To ensure that the pressure relieving properties are not impaired, the cover must not be pulled tight and any covering sheets not fitted too tightly.
  • Page 18: Mode Selection

    CPR Control To perform CPR, pull the CPR tag firmly up and away from the mattress. This will disconnect 2 CPR plugs and rapidly deflate the System. Nimbus Pediatric  On disconection, the mattress replacement will rapidly deflate, sufficient for CPR procedures to commence.
  • Page 19: To Reset Cpr

    To Reset CPR To reset the System after the CPR has Nimbus Pediatric been activated: 1. Push the CPR plugs fully into the holes in the side of the mattress. 2. Close the CPR cover flap using the Velcro provided.
  • Page 20: Controls, Indicators And Alarms

    Controls, Indicators and Alarms Situated on the side panel of the pump, this switches the On/Off Switch (And Alarm Reset) power on and off. It is combined with an internal battery circuit that will activate the alarm system if the power supply is interrupted prior to switching off.
  • Page 21 The pump unit incorporates a sophisticated alarm Alarm Indicator detection system to differentiate between patient movement and genuine alarm conditions. Whenever an alarm occurs, the flashing red indicator is illuminated. Additionally, an audible warning will sound unless cancelled by the button as described earlier.
  • Page 22 New Control Panel Icons A green light on the front panel indicates that the power Power Indicator If the pump detects low pressure in the mattress Wait Indicator replacement, the indicator is illuminated and the WAIT pump performs a start up procedure to inflate the mattress replacement.
  • Page 23 Selects the operating mode, switching between Mode Select Button Dynamic, Static and Autofirm. Indicates that the pump is in Dynamic mode. Dynamic Mode Indicator Indicates that the pump is in Static mode. Static Mode Indicator Indicates that the pump is in Autofirm mode. Autofirm Mode Indicator ...
  • Page 24: Decontamination

    Healthcare Facility or the country of use. If you are uncertain, you should seek advice from your local Infection Control Specialist. system should be routinely decontaminated between patients Nimbus Pediatric and at regular intervals while in use; as is good practice for all reusable medical devices.
  • Page 25 DO NOT WRING/MANGLE, AUTOCLAVE OR USE PHENOLIC BASED SOLUTIONS. For information for the mattress top cover, including Thermal Disinfection laundering guidelines, refer to ‘Cleaning Symbols’ table on page 23.
  • Page 26: Routine Maintenance

    Maintenance maintenance-free between service periods. It is recommended that the pump is serviced annually by a ArjoHuntleigh authorized service agent. ArjoHuntleigh will make available on request service Servicing manuals, component parts lists, and other information necessary for ArjoHuntleigh Healthcare trained personnel to repair the system.
  • Page 27: Troubleshooting

    8. Troubleshooting The following table provides a troubleshooting guide for the Nimbus Pediatric system in the event of malfunction. Possible Indicator Possible Cause Remedy Problem The pump is inflating This indicator will go out the mattress when operating pressure replacement.
  • Page 28: Technical Description

    9. Technical Description PUMP Model: Nimbus Pediatric Part Numbers: 631003 Supply Voltage: 120 VAC Supply Frequency: 60 Hz Power Input: 30 VA Size: 13.2 x 8.3 x 4.0” (336 x 210 x 100 mm) Weight: 7.7 lb (3.5 kg) Case Material:...
  • Page 29: Mattress Size Information

    MATTRESS SIZE INFORMATION Weight Length Width Height Part No. Material 631022 Cover: Polyurethane coated knitted fabric Base: Polyurethane coated woven fabric (5.8 kg) (1300mm) (660mm) (150mm) Cell: 0.3mm (0.012”) Polyurethane flexible sheeting CLEANING SYMBOLS Wash at 80°C (176°F) Do Not Tumble Dry Do not iron Wipe surface with damp cloth Do Not Use Phenol-based cleaning...