AIMS Power PICOGLF10W12V120V User Manual

AIMS Power PICOGLF10W12V120V User Manual

Global lf series pure sine wave inverter charger

Advertisement

Global LF Series Pure Sine Wave Inverter
PICOGLF10W12V120V
PICOGLF20W12V120V
ETL Listed to UL 458 and CSA 22.2 No. 107.1
Charger User's Manual
PICOGLF15W12V120V
PICOGLF30W12V120V

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PICOGLF10W12V120V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AIMS Power PICOGLF10W12V120V

  • Page 1 Global LF Series Pure Sine Wave Inverter Charger User’s Manual PICOGLF10W12V120V PICOGLF15W12V120V PICOGLF20W12V120V PICOGLF30W12V120V ETL Listed to UL 458 and CSA 22.2 No. 107.1...
  • Page 2: Table Of Contents

    AIMS Power www.aimscorp.net Table of Contents 1. Important Safety Information ............................- 2 - 1.1 General Safety Precautions .............................. - 2 - 1.2 Precautions When Working with Batteries ........................- 2 - 2 Introduction ..................................- 3 - 2.1 General Information ................................ - 3 - 2.2 Application ..................................
  • Page 3: Important Safety Information

    AIMS Power www.aimscorp.net 1. Important Safety Information Save This Manual! Read this manual before installation, it contains important safety, installation and operating instructions. Keep it in a safe place for future reference. All wiring must follow the National Electric Code, Provincial or other codes in effect at the time of installation, regardless of suggestions in this manual.
  • Page 4: Introduction

    AIMS Power www.aimscorp.net 1-2-4. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a battery. A battery produces a short-circuit current high enough to weld any metal objects and will cause a severe burn. 1-2-5. To reduce the risk of injury, charge only deep-cycle lead acid, lead antimony, lead calcium gel cell, absorbed mat, NiCad/NiFe and LifePO4 type rechargeable batteries.
  • Page 5: Mechanical Drawing

    AIMS Power www.aimscorp.net 2.3 Mechanical Drawing PICOGLF 1-3KW Models DC Side (Figure 1) Figure 1 PICOGLF 1-3KW Models AC Side (Figure 2) - 4 -...
  • Page 6 AIMS Power www.aimscorp.net Figure 2 PICOGLF 1-3KW Models TOP Side (Figure 3) Figure 3 - 5 -...
  • Page 7: Features

    AIMS Power www.aimscorp.net 2.4 Features High overload ability up to 300% of rated power (20 sec) Low quiescent current, low power “Power Saving Mode” to conserve energy Automatic Generator Start Battery Temperature Sensing for increased charging precision 4-step intelligent battery charger, PFC (Power Factor Correction) for charger...
  • Page 8: Ac Charger

    AIMS Power www.aimscorp.net Overload Capacity The Global LF series inverters have high overload capacities, making it ideal to handle demanding loads. 1 For 110%<Load<125%(±10%), no audible alarm for 14 minutes, beeps 0.5s every 1s in the 15th minute, and Fault (Turn off) after the 15th minute.
  • Page 9 AIMS Power www.aimscorp.net Battery Type selection*). In this stage, the batteries are kept fully charged and ready if needed by the inverter. If the A/C is reconnected or the battery voltage drops below 12Vdc/24Vdc, the charger will restart the above cycle.
  • Page 10 AIMS Power www.aimscorp.net The de-sulphation cycle, switch position 8, is marked in red because this is a very dangerous setting if you do not know what you are doing. Before attempting to use this cycle you must clearly understand what it does and when and how you would use it.
  • Page 11: Transfer

    AIMS Power www.aimscorp.net 2.5.3 Transfer Swift Power Transfer While in the Standby Mode, the AC input of the inverter is continually monitored. Whenever AC power falls below the low AC voltage trip voltage (90VAC default setting for 120VAC), the inverter automatically transfers back to the Invert Mode with minimum power interruption to your appliances - as long as the inverter is turned on.
  • Page 12: The Inverter Is Factory Defaulted To Detect Load For 250Ms Every 3 Seconds. This Power Sensing Can Be Customized To "Unit Off Charging" Via The Sw3 On Dip Switch

    AIMS Power www.aimscorp.net The inverter is factory defaulted to detect load for 250ms every 3 seconds. This power sensing can be customized to “Unit off charging” via the SW3 on DIP switch. Power saver on Power saver off Power saver on (Load detected)
  • Page 13: Remote Control

    AIMS Power www.aimscorp.net The Global LF series inverter is equipped with extensive protections against various harsh situations/faults. These protections include: AC input over voltage protection/AC input low voltage protection Low battery alarm/high battery alarm Over temperature protection/over load protection Short circuit protection (1s after fault)
  • Page 14: Led Indicator

    AIMS Power www.aimscorp.net WARNING Never cut the ethernet cable when the cable is attached to inverter and battery is connected to the inverter. Even if the inverter is turned off, it will damage the remote PCB inside if the cable is short circuited during cutting.
  • Page 15: Fan Operation

    AIMS Power www.aimscorp.net (2)125% <load<150%(±10%), Beeps 0.5s every 1s and Fault after 60s; (3)Load>150%(±10%), Beeps 0.5s every 1s and Fault after 20s; Heat sink temp. ≥105ºC(221℉), Over temp red LED Lighting, beeps 0.5s Over Temperature every 1s; 2.5.9 FAN Operation For 1-3KW models, there is one multiple controlled DC fan which starts to work according to the below logic.
  • Page 16 AIMS Power www.aimscorp.net from over-discharging while there is only a small load applied on the inverter. AC Input Range (SW2): There are different acceptable AC input ranges for different kinds of loads. For some relatively sensitive electronic devices, a narrow input range of 100-135V is required to protect them.
  • Page 17: Auto Generator Start

    AIMS Power www.aimscorp.net Note: In battery priority mode, when qualified AC inputs for the first time and the battery voltage is below 12.5Vdc (12.5Vdc for 12Vdc, 25Vdc for 24Vdc, 51Vdc for 48Vdc), the inverter will go into battery priority mode only after a cycle of bulk charging and absorb charging is finished. The inverter will not go into float charging mode.
  • Page 18: Other Features

    BTS may not be able to properly recharge cold batteries due to maximum voltage limits of the inverter. Ensure the batteries are protected from extreme temperatures. For more detailed technical information, please contact AIMS Power. 2.5.13 Other Features Battery voltage recovery start After low battery voltage shut off, the inverter is able to restore to work after the battery voltage recovers to 13V/26V/52V (with power switch still in “On”...
  • Page 19: Installation

    AIMS Power www.aimscorp.net press"P" Setting 1 OFF time (display 1 off) press H+/M+ Setting hours and minutes turn off time press D+ if you want the same setting everyday,you don\'t need to press this key repeat step 2-6 Setting the 2 to17 ON and OFF time...
  • Page 20: Dc Wiring

    AIMS Power www.aimscorp.net WARNING! The inverter should not be installed in an area that allows dust, fumes, insects or rodents to enter or block the inverter’s ventilation openings. This area also must be free from any risk of condensation, water or any other liquid that can enter or fall on the inverter.
  • Page 21 AIMS Power www.aimscorp.net Power DC Input Wire Gage Battery cables must be crimped (or preferably, soldered and crimped) voltage copper compression lugs unless aluminum mechanical lugs are used. AWG 4 Soldered connections alone are not acceptable. High quality, 1.5KW AWG 1/0 UL-listed battery cables are available.
  • Page 22: Ac Wiring

    AIMS Power www.aimscorp.net 3.4 AC Wiring The AC terminal is rated for wires of 8 AWG to 20 AWG, we recommend using 10 to 8 AWG wire to connect to the ac terminal block. When in AC mode the AC input power will supply both the loads and AC charger, a thicker wire gauge for AC input is required.
  • Page 23 AIMS Power www.aimscorp.net All single phase 120Vac inverters are equipped with automatic neutral-to-ground switching. These inverters use an internal relay that automatically connects the AC neutral output to the vehicle/boat’s safety ground (“bonding” it) in Inverter Mode and disconnects it (“un-bonding” it) when they have connected to a qualified external AC source.
  • Page 24: Mounting The Inverter

    AIMS Power www.aimscorp.net 3.6 Mounting the Inverter To mount the inverter securely, the surface and the mounting hardware must also be able to support at least twice the weight of the inverter. To meet regulatory safety requirements, the PICOGLF Series must be...
  • Page 25 AIMS Power www.aimscorp.net After determining the mounting position, refer to the physical dimensions as shown in below figures or use the base of the inverter as a template to mark your mounting screw locations. After marking the mounting screw locations, mount the unit with appropriate mounting hardware.
  • Page 26: Troubleshooting Guide

    AIMS Power www.aimscorp.net Side View Figure 22 4 Troubleshooting Guide Troubleshooting contains information about how to troubleshoot possible error conditions while using the Global LF Inverter & Charger. The following chart is designed to help you quickly pinpoint the most common inverter failures.
  • Page 27 AIMS Power www.aimscorp.net “Audible Invert Mode alarm” Over-Temp Beep 0.5s √ √ √ √ × × × × × × Invert Mode every 1s Over-Temp Beep 0.5s √ √ √ √ √ × × × × × Line Mode every 1s Beep 0.5s...
  • Page 28 AIMS Power www.aimscorp.net Sensitive loads turn off Inverter's Low voltage trip Choose narrow AC voltage in the temporarily when transferring voltage may be too low to sustain DIP switch, or Install a UPS if between grid and inverting. certain loads.
  • Page 29: Limited Warranty

    In no event shall AIMS be liable for indirect, special or consequential damages. This warranty only applies to AIMS Power branded products. All other name brand products are warranted by and according to their respective manufacturer.
  • Page 30: Appendix 1 - Picoglf Series Spec Sheet

    AIMS Power www.aimscorp.net Appendix 1 - PICOGLF Series Spec Sheet Global Low Freq Series Inverter & AC Charger Electrical Specifications Model 1.5KW Continuous Output Power 1000W 1500W 2000W 3000W Surge Rating(20s) 3000W 4500W 6000W 9000W Capable of Starting Electric Motor 1.5HP...
  • Page 31 AIMS Power www.aimscorp.net Input Voltage Waveform Sine wave (Grid or Generator) Nominal Voltage 120Vac Low Voltage Trip 80V/90V±4% Low Voltage re engage 90V/100V±4% High Voltage Trip 140V±4% High Voltage re engage 135V±4% Max Input AC Voltage 150VAC Nominal Input Frequency 50Hz or 60Hz (Auto detect) Narrow: 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz...
  • Page 32: Appendix 2 - Circuit Schematics

    AIMS Power www.aimscorp.net Appendix 2 - Circuit Schematics Circuitry scheme for models without automatic ground to neutral connection Inverter Mode Figure 31 AC Mode Figure 32 - 31 -...
  • Page 33 AIMS Power www.aimscorp.net Circuitry scheme for models with automatic ground to neutral connection Inverter Mode Figure 33 AC Mode Figure 34 - 32 -...
  • Page 34: Appendix 3 - Installation Diagram

    AIMS Power www.aimscorp.net Appendix 3 - Installation Diagram Figure 35 - 33 -...
  • Page 35: Appendix 4 - Inverter Efficiency

    AIMS Power www.aimscorp.net Appendix 4 - Inverter Efficiency The efficiency varies on different models. For more technical info of our inverters, please contact us: techsupport@aimscorp.net or (775)359-6703. ※Errors and omissions reserved. Specifications in this manual are subject to change without prior notice.
  • Page 36 AIMS Power www.aimscorp.net AIMS OPERATING CORP., INC 9550 GATEWAY DRIVE RENO, NV 89521 TEL: (775) 359-6703 FAX: (775) 359-6753 WWW.AIMSCORP.NET GLOBAL LF SERIES PURE SINE WAVE INVERTER/ CHARGER USER’S MANUAL - 35 -...
  • Page 37 AIMS Power www.aimscorp.net - 36 -...