Thermo Pro 90
Heater
Type approval
Design
Heat flow [kW]
Fuel
Fuel consumption [l/h]
Rated voltage [V]
Operating voltage range [V]
Rated power consumption with coolant pump
and without vehicle blower [W]
Permissible ambient temperature (operation/storage) (including
control unit and coolant pump) [°C]
Altitude suitability, maximum operational altitude above sea level [m]
Max. combustion air intake temperature [°C]
Permissible working pressure of coolant [bar]
Capacity of the heat exchanger [l]
Minimum volume in coolant circuit [l]
Volume flow of coolant pump at 0.15 bar [l/h]
Coolant specification
CO2 in exhaust gas (permitted function range) [Vol %]
CO2-Setting [Vol %] (7.6 kW at full load)
Dimensions of heater (including coolant pump)
See Fig. 2.
Weight [kg]
IP class Heater
ECE R122 (Heating)
ECE R10 (EMC)
Partial load
Full load
Boost (max. 2 h)
Partial load
Full load
Boost
Maximum
Control range
Heater
DP42 fuel pump
Without reduced heating output
With reduced heating output
Length (L) [mm]
Width (W) [mm]
Height (H) [mm]
Technical Information
Thermo Pro 90 Diesel
12 V
E1 122R 00 0320
E1 10R 04 6196
Water heater with vaporising burner
1.8
7.6
9.1
Diesel DIN EN 590, VME DIN EN 14214,
Fuel oil EL DIN 51603-1,
Paraffinic fuel DIN EN 15940 (HVO, GTL)
0.2
0.9
1.1
12
10.5 – 16
≤ 90
37 to 83
–40 to +80 / –40 to +125
–20 to +30 / –40 to +85
< 1500 (high altitude: < 1000)
≤ 3500 (high altitude: ≤ 4500)
+40
2.0
0.15
6.0
1650
See Chapter 6 Integration in the coolant system (on page
45)
9 to 12
10.1 ± 0.4
385
139
219
4.9
IP6K9K
24 V
24
20 – 31
57