WARNING! Risk of Fire! The PowerFlow™ Heat
Management system must remain ON during operation
of the appliance. Overheating will occur. The appliance
will shut down if the heat management systems are not
operational.
The HEAT-ZONE-PRIMO PowerFlow™ Heat Management
System conveys warm air from the fi replace through air
ducts to remote locations in the same room or other rooms
in the building. Two Heat-Zones must be installed with
the Primo appliance or the appliance will overheat. Two
HEAT-ZONE-PRIMO's are included in the kit.
Fan Housing Assembly Installation
Note: The fan and electrical connections must be
accessible for servicing per local code requirements.
2 X 6 Wall Mounting
Mount and secure the fan housing assembly to framing
members so the front surface is 1/4 -in. (6 mm) below the
fi nished wall. Use the adjustable mounting brackets and
screws provided in the kit. See Figure 6.
2 IN. X 6 IN. WALL
FAN HOUSING
ADJUSTABLE MOUNTING
BRACKETS
14 IN.
Figure 6. Wall Mounting (2 X 6)
FINISHED SURFACE
1/4 IN.
(6 MM)
FRONT OF FAN HOUSING
4-1/2 IN.
Heat & Glo • HEAT-ZONE-PRIMO Instructions • 2310-936 Rev. E • 7/16
2 X 4 Wall Mounting
Note: The brackets can be rotated 180º and mounted to
the back side of the 2 x 4 if necessary. See Figure 7.
If the fan housing is installed in a 2 x 4 wall, the front of the
housing will protrude approximately 1/2 in. (13 mm) out of
the wall. See Figure 7.
2 IN. X 4 IN. WALL
FAN HOUSING
14 IN.
Figure 7. Wall Mounting (2 X 4)
FINISHED SURFACE
1/2 IN.
(13 MM)
4-1/2 IN.
5