114
Code
Possible cause
5160
Stitch loosening device
3215
Bobbin stitch counter
(info value 0 reached)
3216
Remaining thread monitor
left
3217
Remaining thread monitor
right
3218
Remaining thread monitor
left and right
3223
Skip stitch detected
3224
Bobbin failed to rotate
6360
No valid data on external
EEprom (internal data
structures are not
compatible with the external
data storage device)
6361
No external EEprom
connected
6362
No valid data on internal
EEprom (internal data
structures are not
compatible with the external
data storage device)
6363
No valid data on internal
and external EEprom
(software version is not
compatible with the internal
data storage device,
emergency operating
features only)
Remedial action
• Stitch loosening cannot be
performed
• Change bobbin, set counter
value
• Change the left bobbin
• Change the right bobbin
• Change the left and right
bobbin
-
-
• Perform software update
• Connect machine ID
• Check machine
ID connection
• Switch off the control, wait
until the LEDs are off and
then switch on the machine
again
• Perform software update
• Check machine
ID connection
• Switch off the control, wait
until the LEDs are off and
then switch on the machine
again
• Perform software update
Operating Instructions 967 - 02.0 - 11/2016