Parameter description
P9.17
P
ARAMETER LOCK
0: Edit enabled
1: Edit disabled
P9.18
R
ESPONSE TO
0: No action
1: Warning
2: Fault, not stored in history
3: Fault, stored in history
Safe Torque Off disabled.
P9.19
R
ESPONSE TO INPUT PHASE FAULT
0: No action
1: Warning
2: Fault
Input phase missing.
P9.20
I
NPUT PHASE FAULT MAX RIPPLE
Sensitivity for input phases check
0: internal value (default)
1-75: sensitivity from maximum(1) to minimum (75)
P9.21
M
OTOR TEMP INITIAL MODE
Setting of estimated motor temperature at power on
0: initialized at minimum value
1: initialized at constant value from P9.22
2: initialized at last previous value, with P9.22 used as factor
P9.22
M
OTOR TEMP INITIAL VALUE
If P9.21= 1, motor temperature is initialized with this value.
If P9.21= 2, motor temperature is initialized with last previous value, multiplied by this value as
% factor.
P9.23
O
UTPUT PHASE FAULT
0: No action
1: Warning
2: Fault
Current measurement has detected that there is no current in one motor phase.