Description of Groups
P4.17
Quick Stop open
P4.18
Stop Mode Activation
(*)The maximum value is higher when an optional board with digital inputs is
NOTE!
installed (see chapter 1.3 and Table 9 for more details). Parameter is automati-
cally reset if value is greater than present limit.
NOTE!
Visibility of the group depends on P1.16.
Option board
installed
OPTB1
OPTB9
OPTBK
Table 9. Maximum value for digital input selection depending on installed option board.
Service support: find your nearest Vacon service center at www.vacon.com
0
6*
0
2
Table 8. Digital inputs parameters.
Maximum value for
digital input selection
12
7
10
If configured, low signal acti-
vates stop with specific ramp.
See P4.1 for selections.
0
1888
NOTE: quick stop function
must be enabled with
P4.18=1
0: normal
1: quick stop
0
1895
2: accurate stop (from Start
signal 1 or 2)
Digital inputs available
DIN7, DIN8, DIN9, DIN10, DIN11, DIN12
DIN7
DIN7, DIN8, DIN9, DIN10