Emptying water from tray
To empty the water remove the plug at the
bottom of the water tray.
Blade Replacement
Remove the cover retaining screws and take off
the blade guard.
Whilst holding the shaft with the spanner wrench,
turn the blade retaining nut clockwise to release
using the hex wrench.
Ensure that the new blade is correctly seated
against the shaft and that the directional arrow
matches that on the blade guard. Replace the
flange and nut, taking care not to overtighten.
Rotate blade to ensure correct alignment.
Replace the blade guard and tighten all parts.
Maintenance
• The machine does not require any special
maintenance.
• Regularly remove grindings from the
housing and the covers.
• The unit must not be operated if the mains
connection lead is not in perfect condition.
• Replacement mains connection leads
must not differ from the versions indicated
by the manufacturer Mains connection
cable: (H05 RN-F 3x1.0 mm²).
• Do not operate a defective unit.
• Servicing only by an authorized
after-sales service point.
• Use only for operations for which the unit
is intended.
Tel: +44 (0) 1253 789180