2. When the mode is enabled, please note the communication of COM2 because the
COM2 is connected to RS-485 network. The RS-485 network is half-duplex.
3. The command can cooperate with the command "$AAEV".
Assume the AA address value of the I-7523 module is 01.
Set COM1: $01E1  Enable the mode of the prefixed address byte on the response.
$01H1 Enable the mode of bypassing the data string to COM2.
Set COM3: $02E1  Enable the mode of the prefixed address byte on the response.
$02H1 Enable the mode of bypassing the data string to COM2.
Assume the data "ABCD(Cr)" is quicker than data "1234".
Bypass data:
!01ABCD(Cr) !021234
I-7521/I-7522/I-7522A/I-7523/I-7524/I-7527 User's Manual,Ver2.5 Aug.2015
Data: ABCD(Cr)
I-7523
COM1
COM2
COM3
Data: 1234
RS-232device