ICP DAS USA I-7521 User Manual page 77

Table of Contents

Advertisement

(2) Valid stop bit values:
I-7521
COM1
1 or 2
(RS-232)
COM2
1
(RS-232)
COM3
N/A
(RS-232)
COM4
N/A
(RS-232)
COM5
N/A
(RS-232)
COM6
N/A
(RS-232)
COM7
N/A
(RS-232)
COM8
N/A
(RS-232)
(3) COM3 of the I-7522A module is RS-422/485
(4) The stop bit for COM1 & COM2 is always 1 when data bit is 8.
(5) COM (1/3/4/5/6/7/8) of the I-7521/I-7522/7523/7523A/7524/7527 module can be
linked to the HP34401A
(6) The stop bit can be set to 2 as the data bit is 7 for COM 1, otherwise the
stop bit can only be set to 1 as the data bit is 8 for COM 1.
I-7521/I-7522/I-7522A/I-7523/I-7524/I-7527 User's Manual,Ver2.5 Aug.2015