Maintenance And Troubleshooting; Troubleshooting - Savant Optical Light Source Manual

Fiber testing kit
Table of Contents

Advertisement

Maintenance and Troubleshooting

1. Always keep the connector ports of the light source clean.
2. Use the regulated optical connector for testing.
3. Shut off the power and cover laser with dust-proof cap after use.
4. When using AC adapter, ensure power supply is within the
required voltage range.
5. Remove the batteries when light source not in use for extended
periods of time.

Troubleshooting

Issue
Faint screen display
Unit fails to turn on
Optical power is not
stable after when
light source turned
on
1. Ensure the connector is clean before testing.
2. Only use the supplied adapter.
3. Do not look into the laser when unit is on.
4. Charge the batteries before use. Do not charge in unit.
5. Cover laser with dust-proof cap when not in operation.
6. Clean the optical port of the power meter regularly.
Handheld Optical Light Source
Possible Reason
Low battery power
Low battery power
or battery inserted
incorrectly
Warning
17
Solution
Charge or replace
the battery.
(A) Replace the
battery
(B) Re-insert the
battery
Allow a 15 minute
warm-up period