Savant® Stand Alone Energy Monitor (SEM-2015)
Quick Reference Guide
Box Contents
(1)
Stand Alone Energy Monitor
(1)
SmartEnergy Voltage Sensor (SEM-VT01-00)
(1)
Install Kit (075-0227-00)
(1)
Universal Din Rail Mounting Clip (015-0255-00)
(1)
Power Supply (025-0192-00)
(1)
6-Pin Screw Down Connector (028-0664-00)
(15) 2-Pin Screw Down Connector (028-0884-00)
(4) #6x1/4 PH Flat Screws (039-0143-00)
(1)
Product Regulatory Insert (009-1808-00)
Accessories (sold separately)
–
SEM-VT01 - SmartEnergy Voltage Sensor
–
Split Core Current Transformers (Clamp-on) with 8ft leads.
–
SEM-020A5
20 Amps
–
SEM-050A5
50 Amps
–
SEM-150A1
150 Amps
–
SEM-150A5
150 Amps
–
SEM-250A1
250 Amps
–
SEM-400A1
400 Amps
–
SEM-600A1
600 Amps
Specifications
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 90% Relative Humidity (non-condensing)
Dimensions and Weight
Height
9.5 in (24.13 cm)
Width
9.7 in (24.64 cm)
Depth
3.3 in (8.38 cm)
Weight
Shipping: 2.65 lb (1.2 kg)
Power
Input Power
5V DC
Nominal Power
3W (10W max)
Regulatory
FCC Part 15B
Safety and
Emissions
RoHS
Compliant
Minimum Support Requirements
Software
da Vinci 9.1
Release
Important Information
–
All wiring in the United States must be installed in accordance with
the latest adopted edition of the National Electrical Code (ANSI/
NFPA 70, NEC).
–
All wiring in Canada must be installed in accordance with the latest
adopted edition of the Canadian Electrical Code (CSA C222.2 CEC,
Part 1) and any provincial or local requirements.
–
Savant's largest Current Transformer supports wire up to 500 MCM
(this with jacket is just under 1 inch).
TIP! MCM refers to circular mils and is often used for wire larger
than the AWG measurement accommodates.
–
Maximum length for leads on each current transformer should not
exceed 8 feet. Longer lengths will cause inaccurate readings.
–
If required, the leads on the current transformers can be shortened.
Stand Alone Energy Monitor | 009-1836-01 | 190703
Copyright 2019 Savant Systems, LLC
5 Pack
5 Pack
1 Pack
5 Pack
1 Pack
1 Pack
1 Pack
CE Mark
C-Tick
Left Side Panel
5 VDC
Ethernet
Status
Reset
(Ground)
Right Side Panel
A
B
C
VT Connections
CT Connections
Current/Voltage Transformer Input Polarity
Current Transformer Input
POS (+) - White or red wire from Current Transformer
GND (-) - Black wire from Current Transformer
POS(+) GND (-)
Voltage Transformer Input
POS (+) - Connect to the positive (+) output on
Voltage Sensor. See diagram in the Install Voltage
Sensors section.
GND (-) - Connect to the GND output of a Voltage
Sensor (SEM-2015). See diagram in Install Voltage
POS(+) GND (-)
Sensors.
1
of
2
Power Input - Connect the supplied power
adapter between the 5V DC port and a surge
protected (120-240V AC, 50/60 Hz) outlet.
8-Pin RJ 45 port. 10/100/1000 BaseT auto-
negotiating port with link activity LEDs
Blinking Red - Embedded firmware is running
but has not received an IP Address.
Solid Green - Connected to the local network
and communicating with the Savant System
Host.
Press and release to perform a hard reset. Status
LED will illuminate while button is pressed.
Device Reset:
1. Disconnect power.
2. Reconnect power wile holding the reset
button for 20 seconds.
Device will reboot clearing its configuration
and resetting its password.
Chassis Ground (optional)
1
2
3
4
5
9
10
11
12
13
Voltage Transformer - (3) Voltage sensor input
ports. Input port for the SEM-VT01 voltage
sensor.
Current Transformer - (15) Input ports for each
Current Transformer installed in the system.
45 Perseverance Way, Hyannis, MA 02601
Savant.com
6
7
8
N/A
14
15
| 508.683.2500