Download Print this page
Savant SEM-2015 Quick Reference Manual

Savant SEM-2015 Quick Reference Manual

Stand alone energy monitor

Advertisement

Quick Links

Savant® Stand Alone Energy Monitor (SEM-2015)
Quick Reference Guide
Box Contents
(1)
Stand Alone Energy Monitor
(1)
SmartEnergy Voltage Sensor (SEM-VT01-00)
(1)
Install Kit (075-0227-00)
(1)
Universal Din Rail Mounting Clip (015-0255-00)
(1)
Power Supply (025-0192-00)
(1)
6-Pin Screw Down Connector (028-0664-00)
(15) 2-Pin Screw Down Connector (028-0884-00)
(4) #6x1/4 PH Flat Screws (039-0143-00)
(1)
Product Regulatory Insert (009-1808-00)
Accessories (sold separately)
SEM-VT01 - SmartEnergy Voltage Sensor
Split Core Current Transformers (Clamp-on) with 8ft leads.
SEM-020A5
20 Amps
SEM-050A5
50 Amps
SEM-150A1
150 Amps
SEM-150A5
150 Amps
SEM-250A1
250 Amps
SEM-400A1
400 Amps
SEM-600A1
600 Amps
Specifications
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 90% Relative Humidity (non-condensing)
Dimensions and Weight
Height
9.5 in (24.13 cm)
Width
9.7 in (24.64 cm)
Depth
3.3 in (8.38 cm)
Weight
Shipping: 2.65 lb (1.2 kg)
Power
Input Power
5V DC
Nominal Power
3W (10W max)
Regulatory
FCC Part 15B
Safety and
Emissions
RoHS
Compliant
Minimum Support Requirements
Software
da Vinci 9.1
Release
Important Information
All wiring in the United States must be installed in accordance with
the latest adopted edition of the National Electrical Code (ANSI/
NFPA 70, NEC).
All wiring in Canada must be installed in accordance with the latest
adopted edition of the Canadian Electrical Code (CSA C222.2 CEC,
Part 1) and any provincial or local requirements.
Savant's largest Current Transformer supports wire up to 500 MCM
(this with jacket is just under 1 inch).
TIP! MCM refers to circular mils and is often used for wire larger
than the AWG measurement accommodates.
Maximum length for leads on each current transformer should not
exceed 8 feet. Longer lengths will cause inaccurate readings.
If required, the leads on the current transformers can be shortened.
Stand Alone Energy Monitor | 009-1836-01 | 190703
Copyright 2019 Savant Systems, LLC
5 Pack
5 Pack
1 Pack
5 Pack
1 Pack
1 Pack
1 Pack
CE Mark
C-Tick
Left Side Panel
5 VDC
Ethernet
Status
Reset
(Ground)
Right Side Panel
A
B
C
VT Connections
CT Connections
Current/Voltage Transformer Input Polarity
Current Transformer Input
POS (+) - White or red wire from Current Transformer
GND (-) - Black wire from Current Transformer
POS(+) GND (-)
Voltage Transformer Input
POS (+) - Connect to the positive (+) output on
Voltage Sensor. See diagram in the Install Voltage
Sensors section.
GND (-) - Connect to the GND output of a Voltage
Sensor (SEM-2015). See diagram in Install Voltage
POS(+) GND (-)
Sensors.
1
of
2
Power Input - Connect the supplied power
adapter between the 5V DC port and a surge
protected (120-240V AC, 50/60 Hz) outlet.
8-Pin RJ 45 port. 10/100/1000 BaseT auto-
negotiating port with link activity LEDs
Blinking Red - Embedded firmware is running
but has not received an IP Address.
Solid Green - Connected to the local network
and communicating with the Savant System
Host.
Press and release to perform a hard reset. Status
LED will illuminate while button is pressed.
Device Reset:
1. Disconnect power.
2. Reconnect power wile holding the reset
button for 20 seconds.
Device will reboot clearing its configuration
and resetting its password.
Chassis Ground (optional)
1
2
3
4
5
9
10
11
12
13
Voltage Transformer - (3) Voltage sensor input
ports. Input port for the SEM-VT01 voltage
sensor.
Current Transformer - (15) Input ports for each
Current Transformer installed in the system.
45 Perseverance Way, Hyannis, MA 02601
Savant.com
6
7
8
N/A
14
15
| 508.683.2500

Advertisement

loading

Summary of Contents for Savant SEM-2015

  • Page 1 Canadian Electrical Code (CSA C222.2 CEC, Part 1) and any provincial or local requirements. – Savant’s largest Current Transformer supports wire up to 500 MCM POS(+) GND (-) (this with jacket is just under 1 inch).
  • Page 2 Mounting Install Voltage Transformer The SEM-2015 can be mounted to either a wall or similar using the pre- Savant requires a licensed electrician be used to connect the SEM- installed Mounting Bracket and the included #6x1/4 PH Flat Screws. VT01 to the high voltage side. Follow instructions below to install. The...

This manual is also suitable for:

Sem-2015-00