Ecoair 920SD WiFi User Manual

Ecoair 920SD WiFi User Manual

X series dc inverter range split type

Advertisement

ecOOI(
X SERIES INVERTER RANGE SPLIT TYPE
Register your air conditioner
Model information can be found on the CE label.
Please register your product online at www.ecoair.org. For future convenience, record the
model information below.
Model Number
Serial Number
Split Air Conditioner
®
DC Inverter
X SERIES 920SD WiFi
X SERIES 1220SD WiFi
X SERIES 1820SD WiFi
X SERIES 2420SD WiFi
_________
\
I
(363/(364-230112

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 920SD WiFi and is the answer not in the manual?

Questions and answers

Summary of Contents for Ecoair 920SD WiFi

  • Page 1 X SERIES 2420SD WiFi _________ Register your air conditioner Model information can be found on the CE label. Please register your product online at www.ecoair.org. For future convenience, record the model information below. Model Number Serial Number Split Air Conditioner...
  • Page 2 To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. WEE/EC2601UR (R32/125:50/50): 1975 © 2018 EcoAir All rights reserved...
  • Page 3: Table Of Contents

    Post Installation Check ............27 Test and operation Test operation ............... 27 Attachment Install snow g uard ( O p tional ) ..........28 Configuration of connection pipe ........... 29 Pipe expanding method ............30 Warranty ................31 © 2018 EcoAir All rights reserved...
  • Page 4: Important Safety Instructions

    Children should be supervised to ensure that they do not play with the appli­ ance. READ & SAVE THESE IMPORTANT SAFETY INSTRUCTIONS FOR FUTURE REFERENCE © 2018 EcoAir All rights reserved...
  • Page 5: Parts

    (Display content or position may be different from above graphics, please refer to actual products) Remote Controller OUTDOOR UNIT Air Inlet Handle Actual product may be different from above graphics, please refer to actual products. © 2018 EcoAir All rights reserved...
  • Page 6: Set Up - Remote Control

    ------------------ --------------------:------ X -f a n m o d e , __________ ) �0.3 9,s· - - � �- · x:x ���������� ���-��� ���N /TIMER O FF �.4 - --�!Offi '- ------------------ Up & down s wi n g © 2018 EcoAir All rights reserved...
  • Page 7: Introduction To Buttons On The Remote Control

    1-Smin. (This time is determined by your indoor ambient temperature) ° ° C to 30 C degrees. * The temperature range you can select between is from l6 * Fan speed can also be adjusted to Auto, Low, Medium or High. © 2018 EcoAir All rights reserved...
  • Page 8 Outdoor temperature display is not available for some models. At that time, indoor unit receives signal, while it displays indoor set temperature. 8} Turbo Button Press this button to activate / deactivate the Turbo function Under COOL or HEAT mode. © 2018 EcoAir All rights reserved...
  • Page 9 • This function is only available for some models. • In order to connect a handheld smartphone, tablet or laptop please visit ecoair.org for fur­ ther instructions. 12) Light Button Press this button to turn on the display's light and press this button again to turn off the display's light.
  • Page 10: Summary Of "Combination Buttons

    Press "TEMP" and "TIMER" simultaneously in HEAT mode to start 8 °C Heating Function ® The remote controller displays and a selected temperature of 8 °C Repeat the op­ • eration to quit the function. * Not all models have this function © 2018 EcoAir All rights reserved...
  • Page 11: Emergency Operation

    If the surface of your unit is dirty we recommend that you use a soft dry cloth to clean. A slightly damp cloth could be used for more stubborn dust and dirt. Note: Do not remove the panel when cleaning it. © 2018 EcoAir All rights reserved...
  • Page 12: Operation Guide

    • When you do not plan on using the remote control for a long time, please remove the batteries. • If the display on remote control is fuzzy or there's no display, please Replace the batteries. © 2018 EcoAir All rights reserved...
  • Page 13: Maintenance Care And Maintenance

    , check and clean more frequently. • After removing the filter, do not touch the fins to avoid injury • Do not use fire or a hair dryer to dry the filter it can cause deformation. © 2018 EcoAir All rights reserved...
  • Page 14 • Many packing materials are recyclable materials. Please dispose of them using an appropriate recycling method. • If you want to dispose of the air conditioner, please contact your local authority or service cen­ ter for the correct disposal method. © 2018 EcoAir All rights reserved...
  • Page 15: Troubleshooting

    Appliance does not respond to Replace the batteries. the remote control. Air conditioner won't operate Wiring has malfunction? Ask qualified engineer to re-wire. Check the setting on the re- Reset the settings. mote controller is correct? © 2018 EcoAir All rights reserved...
  • Page 16 This is the sound of friction caused by expansion Air conditioner has just turned Cracking noise and/or contraction of panel or other parts due to on/off? the change of temperature. © 2018 EcoAir All rights reserved...
  • Page 18: Tools For Installation

    5. Select a location which is out of reach of children and far away from animals or plants. If it is unavoidable, please add a fence or cage for safety purposes. 6. EcoAir recommends that you seek permission from your local authority before any installation. © 2018 EcoAir...
  • Page 19: Requirements For Electrical Connection

    6. Include a circuit breaker with suitable capacity, please note the following table. Circuit breakers should include a magnet buckle with a heating buckle function, it can protect against short-circuits Air-conditioner Circuit break capacity 16A (C Rated) 09K� 12K 25A (C Rated) 18K� 24K © 2018 EcoAir All rights reserved...
  • Page 20: Installation Of Indoor Unit

    ° dient of 5-10 Piping hole Model <DSS Cooling capacity< 6000W <D70 Cooling capacity� 6000W Note: • Pay attention to dust prevention and take relevant safety measures when drilling the hole. © 2018 EcoAir All rights reserved...
  • Page 21 1. Connect the drain hose to the outlet pipe of the indoor unit. 2. Bind the joint with tape. drain hose outlet pipe Note: Add insulating pipe on the indoor drain hose in order to prevent condensation ,-..____ insulating pipe © 2018 EcoAir All rights reserved...
  • Page 22 • The power cord and control wire cant be binding them. When binding to a certain crossed or winding. degree, separate the indoor power and • The drain hose should be bound at the bottom. then separate the drain hose. © 2018 EcoAir All rights reserved...
  • Page 23 5. Check if the indoor unit is installed firmly and close to the wall. upper hook sealing gum � lower hook of � wall-mounting frame Note: • Do not bend the drain hose too excessively this can cause blocking. © 2018 EcoAir All rights reserved...
  • Page 24: Installation Of Outdoor Unit

    Drain � Step three: fix outdoor unit 1. Place the outdoor unit on the support. 2. Fix the foot holes of the outdoor unit with bolts. foot holes ---+--- foot holes © 2018 EcoAir All rights reserved...
  • Page 25 • After tightening the screw, pull the power cord slightly to check if it is firm. • Never cut the power connection wire to prolong or shorten the distance. • EcoAir recommends this to be carried out by an F-GAS Engineer. © 2018 EcoAir...
  • Page 26 The drain hose can't be fluctuant • The water outlet can't be placed in water in order to drain smoothly. � l�tdrainhose n·t be fluctuant The water \;;' __ � The water outlet can't be placed_..::::��� in water © 2018 EcoAir All rights reserved...
  • Page 27: Vacuum Pumping

    If leakage detector is not available, please use soap water for leakage detection. Apply soap water at the suspected position and keep the soap water for more than 3min. If there are air bubbles coming out of this position, there's a leakage. © 2018 EcoAir All rights reserved...
  • Page 28: Post Installation Check

    ° • If the ambient temperature is lower than l6 C , the air conditioner can't start cooling. ECOAIR RECOMMENDS THAT INSTALLATION IS CARRIED OUT BY A QUALIFIED F-GAS ENGINEER © 2018 EcoAir All rights reserved...
  • Page 29: Install Snow Guard (Optional)

    (More than 50cm) Snow guard (Install in windward side) Win � ward side ✓ The snow guard shall be wider than the air conditioner. Height of base in consideration of snow (More than 50cm) © 2018 EcoAir All rights reserved...
  • Page 30: Configuration Of Connection Pipe

    (g/ m) (g/ m) <f:>6 <f:>9.5 or <f:>12 <f:>6 or <f:>9.5 <f:>16 or <f:>19 <f:>12 <f:>19 or <f:>22.2 <f:>25.4 or <f:>31.8 <f:>19 <f:>22.2 Note: The additional refrigerant charging amount in Sheet 2 is recommended © 2018 EcoAir All rights reserved...
  • Page 31: Pipe Expanding Method

    - Remove the union nut on the indoor cording to the steps above connection pipe and outdoor valve; install the union nut on pipe. smooth surface union ipe improper expanding pipe leaning damaged crack uneven surface thickness the length is equal © 2018 EcoAir All rights reserved...
  • Page 32: Warranty

    EcoAir shall not be liable for loss of goods, loss of use, or any special, indirect, consequential or pure eco­ nomic loss, costs, damages, charges or expenses. This does not apply for death or personal injury re­...