Page 1
143x210mm CRYSTAL MK3 9K PAC-100020 PORTABLE AIR CONDITIONER USER MANUAL Please read instruc�ons before use Keep for future reference Visit ecoair.org to register your product @2023 EcoAir - V1.9...
Page 2
BS Plug Wiring The Appliance and Accessories Important Safeguards 5 - 6 Installation 7 - 8 Setup Continuous Drainage for Dry Mode & E4/W.F Control Panel Remote Control Protection Cleaning & Maintenance Storing the Appliance Display Codes Troubleshooting @2023 EcoAir - V1.9...
• The appliance must be installed in accordance with the relevant national legislation. • Should repairs be necessary, contact EcoAir’s Authorised Service Centre. Self-servicing or unauthorised servicing can be dangerous. • The appliance is not intended for use by persons (including children) with reduced physi-...
Page 4
Keep any required ventilation openings clear of obstructions. Never attempt to service or repair the appliances yourself, always ensure it is only serviced by a EcoAir approved engineer using original EcoAir parts. If these appliances are installed, operated or stored in a non-ventilated area, then the room must be designed to prevent the accumulation of refrigerant leaks.
Please note the Earth, Neutral and Live Terminals are marked as E , N and L respec- tively. WEEE COMPLIANT Recycle at your local recycle centre Page 3 @2023 EcoAir - V1.9 All rights reserved (E&OE)
Page 6
Outlet Louvre Exhaust Hose Castor Joint B (Hose to Window) Upper Filter User Manual Air Inlet Grille Remote Control Handle Continuous Drainage Hose 11mm Inner Diameter Lower Filter Continuous Drainage Port Page 4 @2023 EcoAir - V1.9 All rights reserved (E&OE)
Do not place objects on or cover the appliance. FIG 2. Allow at least 50cm of air space on all sides of the appliance for good ventila- tion to avoid overheating. FIG 3. FIG 2. FIG 1. FIG 3. Page 5 @2023 EcoAir - V1.9 All rights reserved (E&OE)
Page 8
3. Ensure that the hose is as straight as possible to ensure the heat is discharged efficiently. If there are kinks in the exhaust hose, the heat will not be dis- charged properly, causing it to overheat which can cause permanent malfunc- tion. Page 6 @2023 EcoAir - V1.9 All rights reserved (E&OE)
3. Seal the gap between the wall and the exhaust hose Joint A Within 130cm Attach Joint A (Hose to AC) B1 to the air outlet slot (at the back of the appliance) Page 7 @2023 EcoAir - V1.9 All rights reserved (E&OE)
Page 10
STEP 4B. DISCHARGE EXHAUST HOSE (B2) THROUGH A WINDOW GAP Pre-seal the window with a Window Seal Nylon Cloth (available for purchase) Pass the exhaust hose B2 (with or without Joint B B3 attached) through the zipped opening. Page 8 @2023 EcoAir - V1.9 All rights reserved (E&OE)
Page 11
Attach a 11mm inner diameter hose Drain the water Reinsert the plug Remove plug from drainage port (A8) Attach supplied 11mm hose (B6) into the port (A8) Page 9 @2023 EcoAir - V1.9 All rights reserved (E&OE)
W.F/E4 on the control panel means empty water tray, the unit will stop until water tray is empty. (See page 9 on how to setup continuous drainage for DRY MODE & E4/W.F) Page 10 @2023 EcoAir - V1.9 All rights reserved (E&OE)
Remote control signal may be interfered within the room where there is wireless telephone, fluorescent lamp. When appliance is not in use for a long time, please remove batteries. Replacement battery (CR2025). Page 11 @2023 EcoAir - V1.9 All rights reserved (E&OE)
Page 14
3 minutes. • If the plug is taken out, when you restart the appliance, it will return to the original mode, TIMER ON and TIMER OFF must be set again. Page 12 @2023 EcoAir - V1.9 All rights reserved (E&OE)
Use vacuum cleaner, brush or water to clean The filter should be cleaned at least once the filter. every two weeks. For dusty environment, you should increase the cleaning frequency . Page 13 @2023 EcoAir - V1.9 All rights reserved (E&OE)
Battery (CR2025) remove. 2. Replace one dry battery (CR2025) and make sure the positions of plus and minus polar are correct. 3. Re-attach the cover of battery box. battery cover Page 14 @2023 EcoAir - V1.9 All rights reserved (E&OE)
LED displays Room temperature sensor fails Replace the room temperature sensor. failure code “E0” or damaged. LED displays Water-full warning. Drain out the water. failure code “E4” Page 15 @2023 EcoAir - V1.9 All rights reserved (E&OE)
Exhaust hose too long or not installed • Check Exhaust hose length is within properly 1.5m and elevation is within 130cm • • Water sound in the Refrigerant or water flowing sound Normal action appliance Page 16 @2023 EcoAir - V1.9 All rights reserved (E&OE)