    You have purchased the very latest in room air conditioning technology. Your new EcoAir high efficiency room appliance will give you many years of dependable service. Many features have been built into your EcoAir portable appliance to assure quiet operation, the best circulation of cool, dry air functional controls and the most economical operation.
  • Page 3: Bs Plug Wiring

    Wiring for a 13 Amp Plug (BS1363) Please note. The Earth Terminal is marked with the letter E or Earth Symbol. Earth - (Green/Yellow) Neutral - N (Blue) Live - L (Brown) © 2016 EcoAir All rights reserved...
  • Page 4: Important Safety Instructions

    Children should be supervised to en- sure that they do not play with the appliance. READ & SAVE THESE IMPORTANT SAFETY INSTRUCTIONS FOR FUTURE REFERENCE © 2016 EcoAir All rights reserved...
  • Page 5: Introduction

    FRONT Control panel Guide louvre (manual) Swing louvre (manual) Castor Power cord hanger Plug of power cord Filter Air Inlet Joint A Discharge pipe Joint B+C (see page 10, step 2) REAR Remote Control © 2016 EcoAir All rights reserved...
  • Page 6: Installation

    (2) screw pipe clamp rubber plug pipe clip Bottom drainage pipe battery (2) (AAA 1.5V) remote control user manual drainage connector TOOLS NEEDED FOR INSTALLATION cross screwdriver straight screwdriver measurement tape scissors pencil © 2016 EcoAir All rights reserved...
  • Page 7 STEP 2. Attach the drain hose pipe clamp to the back Rubber Plug panel of the appliance near the bottom drainage port with Pipe clip the screw provided. Drainage pipe clamp Drainage pipe clamp Drainage pipe Bottom drainage port Drainage clip Screw © 2016 EcoAir All rights reserved...
  • Page 8 The end of the drainage hose should not be outside  Do not bend or kink the drainage hose. when temperature below 1°C. IF ABOVE NOT FOLLOWED, APPLIANCE CAN LEAK WATER! Middle drainage port Drainage hose © 2016 EcoAir All rights reserved...
  • Page 9 Place the appliance in an area where the temperature will not fall below 16°C. Otherwise the coils will be covered with frost at temperatures below 16°C and this may reduce performance. Note: The appliance has castors for easy movement. © 2016 EcoAir All rights reserved...
  • Page 10 Put a 150mm whole through the wall. (outer diameter 142mm) Slide down Joint A to the air outlet  Insert the discharge pipe through the hole.  Seal the gap between the wall and the discharge pipe. Wall Appliance air outlet © 2016 EcoAir All rights reserved...
  • Page 11 STEP 5. DISCHARGE PIPE CONNECTION In order to improve cooling efficiency, make sure the discharge pipe is as short and straight as possi- ble. Do not joint any other discharge pipe to the original pipe. © 2016 EcoAir All rights reserved...
  • Page 12: Installation

    2. Drain the water out completely and the appliance should resume operation. Secure the plug and hose back into position. Rubber Plug Pipe clip Drainage pipe clamp Drainage pipe Drainage clip © 2016 EcoAir All rights reserved...
  • Page 13: Quick Set Up

    DRY: When drying Mode indicator is on, the display shows nothing. Appliance will operate at low speed only. FAN: When fan mode indicator is on, the display shows nothing. The appliance only blows air in the ambient temperature as a fan does. © 2016 EcoAir All rights reserved...
  • Page 14 The preset temperature will increase by 2°C after two hours. The appliance will operate in this temperature until it is switched off.  Use this mode for bedtime, the appliance will reduce the cooling as you fall asleep since our body temperature tends to come down during that period. © 2016 EcoAir All rights reserved...
  • Page 15: Remote Control

    If there is no display on the remote control, please replace batteries. REMOTE CONTROL DISPLAY SCREEN Timer on Timer off Sending signal X-Fan operation Cool operation Sleep operation Dry operation Lock Fan operation Set speed Set temperature Set time © 2016 EcoAir All rights reserved...
  • Page 16: Quick Set Up

    Gently pull clip back on the battery cover to remove. Replace two (AAA 1.5V) dry batteries and make sure the positions of plus and minus polar are correct. Re-attach the cover of battery box. Battery Cover © 2016 EcoAir All rights reserved...
  • Page 17: Cleaning & Maintenance

    2. CLEAN FILTER 3. USEFUL INFORMATION Use vacuum cleaner, brush or water to clean the The filter should be cleaned about once filter. every two weeks. For dusty environment, you should increase the cleaning frequency . © 2016 EcoAir All rights reserved...
  • Page 18: Troubleshooting

    35°C.  Make sure the filters are clean. Overload malfunction  Increase the room temperature Temperature or humidity is  Switch off the appliance until the humidity rises very low again © 2016 EcoAir All rights reserved...
  • Page 19 Appliance cannot receive signal from controller Remote control signal blocked Move away the obstacles. by obstacles. Remote Control is not sensible Appliance does not respond to Replace the batteries. the remote control. © 2016 EcoAir All rights reserved...
  • Page 20 Water Flowing sound from the Refrigerant flowing inside the This is normal. appliance. appliance In the unlikely event of a problem with your product, please refer in the first instance to: ECOAIR TECHNICAL SUPPORT www.ecoair.org/support © 2016 EcoAir All rights reserved...
  • Page 21: Specifications

    CØ 142 mm Net weight 24.5 Kg Gross weight 28 Kg Net Dimension (W x H x D) 315mm x 770mm x 395mm Gross Dimension (W x H x D) 358mm x 881mm x 463mm © 2016 EcoAir All rights reserved...
  • Page 22: Guarantee Card

    However, we will always do our best to assist you in your new country of residence. EcoAir authorises no person to change or add to any obligations under this guarantee. Obligations for service and parts under this guarantee must be performed by EcoAir or an authorised service company.