Page 1
Contact the authorised service technician for repair or maintenance of this unit. Register your air conditioner Model information can be found on the CE label. Please register your product online at www.ecoair.org. For your future convenience, record the model information below. ____________________________________ MODEL NUMBER ____________________________________...
Congratulations! You have purchased the very latest in room air conditioner technology. Your new EcoAir high efficiency room air conditioner will give you many years of dependable service. Many features have been built into your EcoAir air conditioner to assure quiet operation, the best circulation of cool, dry air, functional controls, and the most economical operation.
WARNING: Before operating your unit WARNING Make sure the wiring is adequate for your unit. Before you install or relocate this unit, be sure that the amperage rating of Electrical Shock Hazard the circuit breaker complies with the amp rating listed in Figure 1. Always consult a qualified electrician regarding the power supply to the appliance.
BS Plug Wiring (For models up to 12000 Btu) Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code : BLUE - NEUTRAL BROWN – LIVE GREEN AND YELLOW - EARTH As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:...
Operation and maintenance-notices for operation Earth: The ground Be sure to pull out the power Select the most appropriate tem- be connected! plug when not using the air co- perature. nditioner for a long time. Keep room coo- er than outside about 5 degree.
Notices for operation The airflow direction can be adjusted appro- If the supply cord is damaged, it must be replaced priately. At operating, adjust the vertical airflow by the manufacturer or its service agent or a direction by adjusting the louvers of upward/do- similarly qualified person in order to avoid a wnward direction.
Notices for use Working principle and special functions for cooling Principle: The air conditioner transfers heat from the indoor area to the outdoor area, thus reducing the indoor room temperature, using heat pump technology. Anti-freezing function: In COOL mode under low ambient temperature, frost will form on the heat exchanger. When the indoor heat exchanger temperature decreases to below 0 , the indoor unit microcomputer will stop the compressor from running.
Notices for use Working temperature range Indoor side DB/WB( Outdoor side DB/WB( Maximum cooling 35/24 48/30 21/15 Minimum cooling 21/- Maximum heating 24/--- 21/15.5 Minimum heating 20/--- -15/- The operating temperature range (outdoor temperature) for the cooling is 21 for the heating unit is -15 48 .
Names and functions of wireless remote control Note: Ensure there is no obstruction between the indoor unit and the remote control; Don't drop or throw the remote control; Don't spill any liquid onto remote control. Do not put the remote control directly under the sunlight or heated areas. SLEEP Signal transmitter SLEEP button...
Page 11
Names and functions of wireless remote control + button Remote control - button Press the - button to decrease the setting temp by 1 BLOW BLOW button TEMP TEMP button After powered on, the setting temperature displaying is defaulted, (according to customers requirements to display, if there is no requirement that will default to display the presetting temperature...
Page 12
Names and functions of wireless remote control TIMER ON TIMER ON BUTTON Timer On setting: Signal “ON” will blink and display, signal will conceal, the numerical section will become the timer on setting status. During 5 seconds blink, by pressing button to adjust the time value of numerical section, every press of that button, the value will be...
Page 13
Guide for operation- General operation Guide for operation- Optional operation About AUTO RUN About turbo function...
Page 14
About swing up and down About switch between Fahrenheit and Centigrade Changing batteries and notices NOTE:...
Caution Turn power off and pull out the power plug before cleaning air conditioner, or it may cause shock. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause electric shock. Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.) Clean the front panel When cleaning the front panel, please dip the cloth into the water temperature of 45...
Page 17
Check before use Be sure that nothing obstructs the air outlet and intake vents. Check that ground wire is properly connected or not. (Important) Check that the of the remote control changed if remote is not working. Check that the installation stand of the outdoor unit is damaged or not.
CAUTION Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can save your time and money. Phenomenon Troubleshooting Not operate immediately when the air Once the air conditioner is stopped, it will conditioner is restarted.
Page 19
Troubleshooting Phenomenon Troubleshooting Has the power been shut down? The unit is not running Is power connected properly? Is the circuit protection device tripped off or not? Is voltage higher or lower? (Tested by professionals) Breaking off Is the TIMER correctly used? Is Temp.
Page 20
Troubleshooting Phenomenon Troubleshooting No air delivery from indoor unit. In HEAT mode, when the indoor temperature is very low, air delivery will be delayed for up to 5 minutes. In HEAT mode, when the outdoor temperature is low or high humidity, frost may from on the outdoor heat exchanger.
Notices for installation Important Notices When removing the unit to the other place, please firstly contact with the authorized Maintenance Center in the local area. Basic Requirements For Installation Position Install in the following place may cause malfunction. If it is unavoidable contact with service center please: Place where strong heat sources, vapors, flammable gas or volatile obj ct are emitted.
Page 22
Safety Requirements For Electric Appliances 1. The power supply should be used the rated voltage and AC exclusive circuit, the power cable diameter should be satisfied. Don't drag the power cable emphatically. It should be reliably earthed, and it should be connected to the special earth device, the installation work should be operated by the professional.
Ready for the following tools: Electric SDS drill. (If you use an ordinary drill you Hammer will need an SDS adaptor) Screwdrivers. Posidrive Tape measure or crosshead Spirit level Prepare hole cutter Number 14 (7mm) Pencil and chalk masonary drill 1.5 inch number Small stepladder 10 screws.
Page 25
Ready for the following tools: 2 inch Pipe clips Circuit breaker when drilling inside and out Garden gloves when lifting the outdoor unit Dustsheets Foam Filler Silicone sealer and gun...
1. Check the area for any 2. Mark the righthand 3. Remove the backplate hidden wires or pipes. backplate screw and drill a 7mm hole. position. 4. Tap home a 7mm 5. Screw the backplate 6. Check level, mark the wallplug.
Page 27
13. Undo the power lead 14. Hook the indoor unit 15. Lock the bottom of the and break out the onto the top of the unit onto the base of plastic lead tab. backplate. the backplace. downward slant to the Ø...
1. Gently bend the pipe 2. Mark a vericle chalk 3. Mark a chalk line on at right angles to the line on the wall using the floor to line up the wall. a spirit level. outside unit with the connecting cord 4.
Page 30
1. Push the drain hose onto 2. Remove the raincover 3. Slide the lug towards the indoor unit outlet. from the side (Indoor left side (1) from female Unit). coupling. 4. Push the male coupling 5. Close the retaining clip (4), 6.
Page 31
To Connect the couplings Step 1: Ensure that the handle on the male coupling is in a reclined position away from the mating male coupling. Step 2: Retract the “Release Sleeve” on female coupling, insert the male coupling located on the indoor unit into the female coupling.
Page 32
Connect indoor and outdoor electric wires When outdoor ambient sensor malfunction happened, both of the electric heating belts stop working, otherwise, it will run at the following control:.When Toutdoor ambient =-5. and the compressor doesn't started, that the compressor electric heating belt starts to work; Otherwise if compressor started or compressor doesn't start but Toutdoor ambient>-2.
Quick coupling Electric wiring Disassemble the handle on the outdoor unit right side plate. Take off wire clamp. Connect and fix power connect cord (for cooling and heating unit,connect and fix power connect cord and signal control wire)to terminal of line bank.
Check after installation and test operation Check after installation Items to be checked Possible malfunction Has it been fixed firmly? The unit may drop, shake or emit noise. It may cause insufficient cooling(heating) Have you done the refrigerant leakage test? capacity It may cause condensation and dripping.
ONE (1) YEAR LIMITED WARRANTY SAVE THIS WARRANTY INFORMATION EcoAir guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically excluded.
Need help?
Do you have a question about the ECO906SQ and is the answer not in the manual?