Using The Allen Key; Cleaning The Outer Housing And Cup Warming Tray; Storage - Sage Barista Express BES875 Quick Manual

Hide thumbs Also See for Barista Express BES875:
Table of Contents

Advertisement

Available languages

Available languages

The storage tray (located behind the drip tray)
can be removed and cleaned with a soft, damp
cloth. Do not use abrasive cleansers, pads
or cloths which can scratch the surface.
NOTE
All parts should be cleaned by hand using warm
water and a gentle dish washing liquid. Do not
use abrasive cleansers, pads or cloths which
can scratch the surface. Do not clean any of the
parts or accessories in the dishwasher.
CLEANING THE OUTER HOUSING
& CUP WARMING TRAY
The outer housing and cup warming tray can
be cleaned with a soft, damp cloth. Polish with
a soft, dry cloth. Do not use abrasive cleansers,
pads or cloths which can scratch the surface.
STORING YOUR MACHINE
Before storing, ensure the STEAM / HOT
WATER dial is in the STANDBY position, press
the POWER button to switch the machine off
and remove the plug from the power outlet.
Remove unused beans from the hopper, clean
the grinder (see page 16), empty the water
tank and the drip tray.
WARNING
Do not immerse power cord, power plug
or appliance in water or any other liquid.

USING THE ALLEN KEY

Over time, the silicone seal surrounding
the shower screen will need to be replaced
to ensure optimum brewing performance.
1. Press the POWER button to switch the
machine off and unplug the cord from the
power outlet.
2. Carefully remove the water tank and drip tray,
taking particular care if they are full.
3. Using a skewer or similar, clean the centre
of the screw of any residual coffee.
4. Insert the shorter end of the Allen Key into
the centre of the screw. Turn counter-clockwise
to loosen the screw.
Clean centre of screw
before inserting Allen Key
5. Once loosened, carefully remove and retain the
screw, stainless steel shower screen and black
dispersion plate. Make note of the side of the
shower screen and dispersion plate that are
facing downwards. This will make re-assembly
easier. Wash the shower screen and dispersion
plate in warm soapy water, then dry thoroughly.
6. Remove the silicone seal with your fingers
or a pair of long-nose pliers. Insert the new seal,
flat side first, so the ribbed side is facing you.
7. Re-insert the dispersion plate, then the shower
screen, then the screw. With your fingers, turn
the screw clockwise for 2-3 revolutions then
insert the Allen Key to tighten until the screw
is flush with the shower screen.
8. Re-insert the drip tray and water tank.
Contact Sage Customer Service or visit
www.sageappliances.com for replacement
silicone seals or for advice.