12.5 Seat depth adjustments: (Fig. 12.5).

Remove the 2 bolts on the backrest brackets 1 for each
side of the frame, using a 6mm Allen key and 13.0mm
spanner. Move the backrest into the seat depth position
required. Re-assemble bolts and tighten to a torque of
17-20Nm. To compensate for the armrest position, both
the sideguard and the armpad are adjustable.
There are 5 Seat depths; 410 to 510mm in 25mm steps.

12.6 Control Adjustment (Fig. 12.6):

The control can be adjusted to various positions by pushing
it along the armrest. The control can be moved by turning
the lever below the arm pad anti-clockwise, reposition the
controller and secure by turning the lever clockwise to tighten.
WARNING!
• Do not replace the joystick knob with any unauthorised
item. It may cause hazardous operation and loss of
control of the chair.
• It is important that the joystick boot is replaced if it is torn
or brittle; failure to do so could cause substance damage
to the controller and unexpected movement of the chair.
• Ensure that you always have comfortable access to the
controls whilst the chair is moving and make sure that
the controller is fixed securely to the chair.

12.7 Dual/Attendant control (Where fitted)

WARNING!
• Ensure that you set the speed of the attendant control to
a speed that you can comfortably follow.
• Always turn off the power to the controller when leaving
the user in the chair. (See sections 9.10 - 9.14).
42
Q100R Q200R Rev. A

12.8 Parallel swing-away control (Fig.12.7):

WARNING!
• Before adjusting the swing-away arm, switch off the
controller to avoid accidental displacement of the
joystick which would cause unwanted movement of your
wheelchair.
• Keep your fingers and clothing, etc. clear while operating
the swing-away mechanism.
• Be aware that the width of your chair has increased if
the swing-away arm is out and you may not get between
certain obstacles.
• Do not hang any items on or over the parallel swing-away
remote assembly as this could damage the swing-away
mechanism.
• When transferring to and from the wheelchair do not use
the remote as a means of support.
• Keep fingers, clothing, etc. clear of the swing-away
mechanism at all times.
• Ensure the power is switched off while adjusting the
parallel swing-away arm.
Fig. 12.5
• Only operate the wheelchair at low manoeuvring speed
when the parallel swing-away is in use, (Fig.12.6).

12.9 Programming:

When the chair leaves the factory, the parameters of the
controller are set to default. However, if any alterations are
required, then you should contact your dealer, where a
specialist can carry out this work.
Fig. 12.6
Note: A programmer or a PC-based software program with
the appropriate connecting lead are required to program
the wheelchair.
WARNING!
Never attempt to programme the wheelchair yourself.
WARNING!
Programming the controller of the wheelchair is only
allowed through authorised personnel trained by Sunrise
Medical. Incorrect controller settings could cause driving
outside the safe limits and could result in damage or injury.
Fig. 12.7